» Articles » PMID: 22841651

The Use of Near-infrared Light for Safe and Effective Visualization of Subsurface Blood Vessels to Facilitate Blood Withdrawal in Children

Overview
Journal Med Eng Phys
Date 2012 Jul 31
PMID 22841651
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Obtaining access to blood vessels can be difficult, especially in children. Visualization of subsurface blood vessels might be a solution. Ultrasound and visible light have been used to this purpose, but have some drawbacks. Near-infrared light might be a better option since subsurface blood vessels can be visualized in high contrast due to less absorption and scattering in tissue as compared to visible light. Our findings with a multispectral imaging system support this theory. A device, the VascuLuminator, was developed, based on transillumination of the puncture site with near-infrared light. The VascuLuminator was designed to meet the requirements of compact and safe use. A phantom study showed that the maximum depth of visibility (5.5mm for a 3.6mm blood vessel) is sufficient to visualize blood vessels in typical locations for peripheral venous and arterial access. A quantitative comparison of the VascuLuminator and to two other vessel imaging devices, using reflection of near-infrared light instead of transillumination, was conducted. The VascuLuminator is able to decrease failure at first attempt in blood withdrawal in pediatric patients from 10/80 (13%) to 1/45 (2%; P=.05).

Citing Articles

A large open access dataset of transillumination imaging the toward realization of optical computed tomography.

Phan Van T, Huynh H, Nguyen N, Tran T, Shimizu K Sci Data. 2025; 12(1):388.

PMID: 40050312 PMC: 11885589. DOI: 10.1038/s41597-025-04626-4.


Engineering vascularized skin-mimetic phantom for non-invasive Raman spectroscopy.

Raj P, Wu L, Arora S, Bhatt R, Zuo Y, Fang Z Sens Actuators B Chem. 2024; 404.

PMID: 38524639 PMC: 10956615. DOI: 10.1016/j.snb.2023.135240.


HyperVein: A Hyperspectral Image Dataset for Human Vein Detection.

Ndu H, Sheikh-Akbari A, Deng J, Mporas I Sensors (Basel). 2024; 24(4).

PMID: 38400276 PMC: 10891899. DOI: 10.3390/s24041118.


Noninvasive optical monitoring of pulmonary embolism: a Monte Carlo study on visible Chinese human thoracic tissues.

Meng S, Su H, Guo J, Wang L, Li T J Biomed Opt. 2023; 28(1):015001.

PMID: 36688229 PMC: 9847892. DOI: 10.1117/1.JBO.28.1.015001.


U-DAVIS-Deep Learning Based Arm Venous Image Segmentation Technique for Venipuncture.

Kuthiala A, Tuli N, Singh H, Boyraz O, Jindal N, Mavuduru R Comput Intell Neurosci. 2022; 2022:4559219.

PMID: 36238666 PMC: 9553422. DOI: 10.1155/2022/4559219.