» Articles » PMID: 22814903

Penetration of Fluorescein Across the Rabbit Cornea from the Endothelial Surface

Overview
Journal Pharm Res
Specialties Pharmacology
Pharmacy
Date 2012 Jul 21
PMID 22814903
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To model the kinetics of penetration of fluorescein across the cornea from the endothelial surface.

Methods: Rabbit corneas mounted in vitro were exposed to fluorescein at their endothelial surface. Trans-corneal fluorescence were acquired periodically for 6 h using a custom-built confocal microfluorometer. The profiles were then employed to fit a kinetic model for calculation of permeability and diffusion coefficients across the cellular layers and stroma, respectively.

Results: At the endothelium-stroma and stroma-epithelium interfaces, the fluorescence profile exhibited sudden jumps. In each case, the fluorescence was higher at the stroma, indicating reduced partitioning of the dye into the lipid-rich cellular layers. The stroma did not swell significantly until 180 min of perfusion. The fluorescence profiles reached a pseudo-steady state at ~6 h. A transport model, which included convective and diffusive fluxes into the stroma, showed a good fit to the trans-corneal profiles at different time points. The estimated permeability coefficients for the cellular layers were close to the values reported previously, but the diffusion coefficient of fluorescein in the stroma was found to be smaller than the values obtained previously using Ussing chambers.

Conclusions: The penetration of fluorescein could be modeled accurately by a combination of diffusion and convection.

Citing Articles

Imaging-Based Drug Penetration Profiling in an Excised Sheep Cornea Model.

Viehmeister K, Manuelli A, Guerin C, Kappes S, Lamprecht A Pharmaceutics. 2024; 16(9).

PMID: 39339164 PMC: 11435002. DOI: 10.3390/pharmaceutics16091126.


Endothelial tissue remodeling induced by intraluminal pressure enhances paracellular solute transport.

Cacheux J, Bancaud A, Alcaide D, Suehiro J, Akimoto Y, Sakurai H iScience. 2023; 26(7):107141.

PMID: 37416478 PMC: 10320514. DOI: 10.1016/j.isci.2023.107141.


Asymmetry in Drug Permeability through the Cornea.

Toffoletto N, Chauhan A, Alvarez-Lorenzo C, Saramago B, Serro A Pharmaceutics. 2021; 13(5).

PMID: 34064834 PMC: 8151369. DOI: 10.3390/pharmaceutics13050694.


Corneal epithelial permeability to fluorescein in humans by a multi-drop method.

Srinivas S, Goyal A, Talele D, Mahadik S, Sudhir R, Murthy P PLoS One. 2018; 13(6):e0198831.

PMID: 29920519 PMC: 6007839. DOI: 10.1371/journal.pone.0198831.


Computational modeling of drug transport across the in vitro cornea.

Pak J, Chen Z, Sun K, Przekwas A, Walenga R, Fan J Comput Biol Med. 2017; 92:139-146.

PMID: 29175100 PMC: 5766268. DOI: 10.1016/j.compbiomed.2017.11.009.

References
1.
Araie M, MAURICE D . A reevaluation of corneal endothelial permeability to fluorescein. Exp Eye Res. 1985; 41(3):383-90. DOI: 10.1016/s0014-4835(85)80029-4. View

2.
Araie M . Kinetics of intraocular penetration of topical fluorescein: analysis by new method. Jpn J Ophthalmol. 1983; 27(3):421-33. View

3.
Levick J . Flow through interstitium and other fibrous matrices. Q J Exp Physiol. 1987; 72(4):409-37. DOI: 10.1113/expphysiol.1987.sp003085. View

4.
Srinivas S . Dynamic regulation of barrier integrity of the corneal endothelium. Optom Vis Sci. 2010; 87(4):E239-54. PMC: 2868144. DOI: 10.1097/OPX.0b013e3181d39464. View

5.
Araie M, Maurice D . The rate of diffusion of fluorophores through the corneal epithelium and stroma. Exp Eye Res. 1987; 44(1):73-87. DOI: 10.1016/s0014-4835(87)80027-1. View