Lung Ultrasound in the Diagnosis and Follow-up of Community-acquired Pneumonia: a Prospective, Multicenter, Diagnostic Accuracy Study
Overview
Authors
Affiliations
Background: The aim of this prospective, multicenter study was to define the accuracy of lung ultrasound (LUS) in the diagnosis of community-acquired pneumonia (CAP).
Methods: Three hundred sixty-two patients with suspected CAP were enrolled in 14 European centers. At baseline, history, clinical examination, laboratory testing, and LUS were performed as well as the reference test, which was a radiograph in two planes or a low-dose CT scan in case of inconclusive or negative radiographic but positive LUS findings. In patients with CAP, follow-up between days 5 and 8 and 13 and 16 was scheduled.
Results: CAP was confirmed in 229 patients (63.3%). LUS revealed a sensitivity of 93.4% (95% CI, 89.2%-96.3%), specificity of 97.7% (95% CI, 93.4%-99.6%), and likelihood ratios (LRs) of 40.5 (95% CI, 13.2-123.9) for positive and 0.07 (95% CI, 0.04-0.11) for negative results. A combination of auscultation and LUS increased the positive LR to 42.9 (95% CI, 10.8-170.0) and decreased the negative LR to 0.04 (95% CI, 0.02-0.09). We found 97.6% (205 of 211) of patients with CAP showed breath-dependent motion of infiltrates, 86.7% (183 of 211) an air bronchogram, 76.5% (156 of 204) blurred margins, and 54.4% (105 of 193) a basal pleural effusion. During follow-up, median C-reactive protein levels decreased from 137 mg/dL to 6.3 mg/dL at days 13 to 16 as did signs of CAP; median area of lesions decreased from 15.3 cm2 to 0.2 cm2 and pleural effusion from 50 mL to 0 mL.
Conclusions: LUS is a noninvasive, usually available tool used for high-accuracy diagnosis of CAP. This is especially important if radiography is not available or applicable. About 8% of pneumonic lesions are not detectable by LUS; therefore, an inconspicuous LUS does not exclude pneumonia.
Ajmire P, Deshpande V, Haseeb M, Nelanuthala M, Khanna S Cureus. 2025; 17(1):e77158.
PMID: 39925588 PMC: 11806391. DOI: 10.7759/cureus.77158.
Hsu N, Lin Y, Tsai H, Huang T, Hsu C Diagnostics (Basel). 2025; 14(24.
PMID: 39767160 PMC: 11674558. DOI: 10.3390/diagnostics14242799.
Lung ultrasound in pneumonia: a guide for effective implementation.
Kok B, Tuinman P, Haaksma M Intern Emerg Med. 2024; .
PMID: 39656349 DOI: 10.1007/s11739-024-03807-0.
Point-of-care lung ultrasound in the diagnosis of childhood pneumonia.
Vaitheeswaran G, Velmurugan L, Jayabalan R, Kalpana S Lung India. 2024; 41(6):411-415.
PMID: 39465919 PMC: 11627350. DOI: 10.4103/lungindia.lungindia_574_23.
Wang Q, Zou T, Zeng X, Bao T, Yin W BMC Pulm Med. 2024; 24(1):483.
PMID: 39363211 PMC: 11450992. DOI: 10.1186/s12890-024-03299-w.