» Articles » PMID: 22645466

Effect of Human and Bovine Serum Albumin on Kinetic Chemiluminescence of Mn (III)-Tetrakis (4-sulfonatophenyl) Porphyrin-luminol-hydrogen Peroxide System

Overview
Publisher Wiley
Specialty Biology
Date 2012 May 31
PMID 22645466
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

The present work deals with an attempt to study the effect of human and bovine serum albumin on kinetic parameters of chemiluminescence of luminol-hydrogen peroxide system catalyzed by manganese tetrasulfonatophenyl porphyrin (MnTSPP). The investigated parameters involved pseudo-first-order rise and fall rate constant for the chemiluminescence burst, maximum level intensity, time to reach maximum intensity, total light yield, and values of the intensity at maximum CL which were evaluated by nonlinear least square program KINFIT. Because of interaction of metalloporphyrin with proteins, the CL parameters are drastically affected. The systems resulted in Stern-Volmer plots with k(Q) values of 3.17 × 10(5) and 3.7 × 10(5) M(-1) in the quencher concentration range of 1.5 × 10(-6) to 1.5 × 10(-5) M for human serum albumin (HSA) and bovine serum albumin (BSA), respectively.

Citing Articles

A tannic acid doped hydrogel with small extracellular vesicles derived from mesenchymal stem cells promotes spinal cord repair by regulating reactive oxygen species microenvironment.

Liu Z, Guo S, Dong L, Wu P, Li K, Li X Mater Today Bio. 2022; 16:100425.

PMID: 36186847 PMC: 9523385. DOI: 10.1016/j.mtbio.2022.100425.

References
1.
Daneshgar P, Moosavi-Movahedi A, Norouzi P, Ganjali M, Madadkar-Sobhani A, Saboury A . Molecular interaction of human serum albumin with paracetamol: spectroscopic and molecular modeling studies. Int J Biol Macromol. 2009; 45(2):129-34. DOI: 10.1016/j.ijbiomac.2009.04.011. View

2.
Wang Z, Song Z, Chen D . Study on the binding behavior of bovine serum albumin with cephalosporin analogues by chemiluminescence method. Talanta. 2010; 83(2):312-9. DOI: 10.1016/j.talanta.2010.09.029. View

3.
Li Y, Zhao D, Zhu C, Wang L, Xu J . Determination of proteins at nanogram levels by their quenching effect on the chemiluminescence reaction between luminol and hydrogen peroxide with manganese-tetrasulfonatophthalocyanine as a new catalyst. Anal Bioanal Chem. 2002; 374(3):395-8. DOI: 10.1007/s00216-002-1498-1. View

4.
Xu W, Wei Y, Xing D, Chen Q . A novel chemiluminescence technique for quantitative measurement of low concentration human serum albumin. Anal Sci. 2008; 24(1):115-9. DOI: 10.2116/analsci.24.115. View

5.
Lin J, Ju H . Electrochemical and chemiluminescent immunosensors for tumor markers. Biosens Bioelectron. 2005; 20(8):1461-70. DOI: 10.1016/j.bios.2004.05.008. View