» Articles » PMID: 22592900

Off-Pump Coronary Artery Bypass Surgery is Associated with Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization: Results from the Veterans Affairs Randomized On/Off Bypass (ROOBY) Trial

Overview
Journal Circulation
Date 2012 May 18
PMID 22592900
Citations 52
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques.

Methods And Results: From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angiography was obtained in 685 off-pump (62%) and 685 on-pump (62%) patients. Angiograms were analyzed (blinded to treatment) for FitzGibbon classification (A=widely patent, B=flow limited, O=occluded) and effective revascularization. Effective revascularization was defined as follows: All 3 major coronary territories with significant disease were revascularized by a FitzGibbon A-quality graft to the major diseased artery, and there were no new postanastomotic lesions. Off-pump CABG resulted in lower FitzGibbon A patency rates than on-pump CABG for arterial conduits (85.8% versus 91.4%; P=0.003) and saphenous vein grafts (72.7% versus 80.4%; P<0.001). Fewer off-pump patients were effectively revascularized (50.1% versus 63.9% on-pump; P<0.001). Within each major coronary territory, effective revascularization was worse off pump than on pump (all P≤0.001). The 1-year adverse cardiac event rate was 16.4% in patients with ineffective revascularization versus 5.9% in patients with effective revascularization (P<0.001).

Conclusions: Off-pump CABG resulted in significantly lower FitzGibbon A patency for arterial and saphenous vein graft conduits and less effective revascularization than on-pump CABG. At 1 year, patients with less effective revascularization had higher adverse event rates.

Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00032630.

Citing Articles

Surgical Management of Ischemic Heart Disease Patients With Left Ventricular Dysfunction in Lower-Middle-Income Countries: Our Strategies and Experience at the Medical Teaching Institute-Hayatabad Medical Complex (MTI-HMC) Peshawar, Pakistan.

Aasim M, Khan R, Mohsin A, Ikram J, Aziz R, Zahid A Cureus. 2025; 17(1):e77063.

PMID: 39917095 PMC: 11801806. DOI: 10.7759/cureus.77063.


Angiographic Outcomes for Arterial and Venous Conduits Used in CABG.

Dimagli A, Soletti Jr G, Harik L, Olaria R, Cancelli G, An K J Clin Med. 2023; 12(5).

PMID: 36902809 PMC: 10004690. DOI: 10.3390/jcm12052022.


Experience, exposure, and attitudes regarding off-pump coronary artery bypass grafting techniques in US cardiothoracic surgical residents: Results of a survey.

Kashyap A, Qin A, Rabkin D, Toporoff B JTCVS Open. 2023; 12:192-200.

PMID: 36590737 PMC: 9801275. DOI: 10.1016/j.xjon.2022.10.002.


Objective improvement with coronary anastomosis simulation training: meta-analysis.

ODwyer M, Fleming C, Ahern S, Barrett S, Raftery N, Dhonnchu T BJS Open. 2022; 6(1).

PMID: 35143631 PMC: 8830760. DOI: 10.1093/bjsopen/zrab147.


Long-Term Follow-Up of Device-Assisted Clampless Off-Pump Coronary Artery Bypass Grafting Compared with Conventional On-Pump Technique.

Bassano C, Nardi P, Buioni D, Asta L, Pisano C, Bertoldo F Int J Environ Res Public Health. 2022; 19(1).

PMID: 35010535 PMC: 8750984. DOI: 10.3390/ijerph19010275.