Optimised in Vitro Applicable Loads for the Simulation of Lateral Bending in the Lumbar Spine

Overview
Journal Med Eng Phys
Date 2012 May 8
PMID 22560004
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

In in vitro studies of the lumbar spine simplified loading modes (compressive follower force, pure moment) are usually employed to simulate the standard load cases flexion-extension, axial rotation and lateral bending of the upper body. However, the magnitudes of these loads vary widely in the literature. Thus the results of current studies may lead to unrealistic values and are hardly comparable. It is still unknown which load magnitudes lead to a realistic simulation of maximum lateral bending. A validated finite element model of the lumbar spine was used in an optimisation study to determine which magnitudes of the compressive follower force and bending moment deliver results that fit best with averaged in vivo data. The best agreement with averaged in vivo measured data was found for a compressive follower force of 700 N and a lateral bending moment of 7.8 Nm. These results show that loading modes that differ strongly from the optimised one may not realistically simulate maximum lateral bending. The simplified but in vitro applicable loading cannot perfectly mimic the in vivo situation. However, the optimised magnitudes are those which agree best with averaged in vivo measured data. Its consequent application would lead to a better comparability of different investigations.

Citing Articles

Load Changes on a Short-Segment Posterior Instrumentation After Transosseous Disruption of L3 Vertebra - A Biomechanical Human Cadaveric Study.

Heumann M, Jacob A, Gueorguiev B, Geoff Richards R, Benneker L Global Spine J. 2024; :21925682241282276.

PMID: 39214863 PMC: 11571447. DOI: 10.1177/21925682241282276.


The effect of large channel-based foraminoplasty on lumbar biomechanics in percutaneous endoscopic discectomy: a finite element analysis.

Sun W, Li D, Zhao S, Fu H, Tian J, Zhang F J Orthop Surg Res. 2024; 19(1):402.

PMID: 38997769 PMC: 11241959. DOI: 10.1186/s13018-024-04870-1.


Validation and Estimation of Obesity-Induced Intervertebral Disc Degeneration through Subject-Specific Finite Element Modelling of Functional Spinal Units.

Singh N, Singh N, Verma R, Diwan A Bioengineering (Basel). 2024; 11(4).

PMID: 38671766 PMC: 11048157. DOI: 10.3390/bioengineering11040344.


Anatomical parameters alter the biomechanical responses of adjacent segments following lumbar fusion surgery: Personalized poroelastic finite element modelling investigations.

Nikkhoo M, Chen W, Lu M, Fu C, Niu C, Lien H Front Bioeng Biotechnol. 2023; 11:1110752.

PMID: 36860879 PMC: 9968854. DOI: 10.3389/fbioe.2023.1110752.


Optimization of a lumbar interspinous fixation device for the lumbar spine with degenerative disc disease.

Heo M, Yun J, Kim H, Lee S, Park S PLoS One. 2022; 17(4):e0265926.

PMID: 35390024 PMC: 8989208. DOI: 10.1371/journal.pone.0265926.