» Articles » PMID: 22515905

Reduction of Hard-tissue Debris Accumulation During Rotary Root Canal Instrumentation by Etidronic Acid in a Sodium Hypochlorite Irrigant

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 2012 Apr 21
PMID 22515905
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Hard-tissue debris is accumulated during rotary instrumentation. This study investigated to what extent a calcium-complexing agent that has good short-term compatibility with sodium hypochlorite (NaOCl) could reduce debris accumulation when applied in an all-in-one irrigant during root canal instrumentation.

Methods: Sixty extracted mandibular molars with isthmuses in the mesial root canal system were selected based on prescans using a micro-computed tomography system. Thirty teeth each were randomly assigned to be instrumented with a rotary system and irrigated with either 2.5% NaOCl or 2.5% NaOCl containing 9% (wt/vol) etidronic acid (HEBP). Using a side-vented irrigating tip, 2 mL of irrigant was applied by 1 blinded investigator to the mesial canals after each instrument. Five milliliters of irrigant was applied per canal as the final rinse. Mesial root canal systems were scanned at high resolution before and after treatment, and accumulated hard-tissue debris was calculated as vol% of the original canal anatomy. Values between groups were compared using the Student's t test (α < .05).

Results: Irrigation with 2.5% NaOCl resulted in 5.5 ± 3.6 vol% accumulated hard-tissue debris compared with 3.8 ± 1.8 vol% when HEBP was contained in the irrigant (P < .05).

Conclusions: A hypochlorite-compatible chelator can reduce but not completely prevent hard-tissue debris accumulation during rotary root canal instrumentation.

Citing Articles

Vertical root fractures and cracked teeth: post-endodontic root dentinal status through micro-CT assessment after ex vivo fiber post removal.

Cavalcante D, Tavares S, Purger L, Scelza P, Gallito M, Saddock A Clin Oral Investig. 2024; 29(1):32.

PMID: 39730834 DOI: 10.1007/s00784-024-06116-0.


Comparative evaluation of continuous and sequential chelation on the dentinal tubule penetration of bioceramic-based sealer - A confocal laser scanning microscopic study.

Gupta K, Shetty S, Tandale A, Srikurmam M, Nihalani H J Conserv Dent Endod. 2024; 27(9):935-941.

PMID: 39450360 PMC: 11498235. DOI: 10.4103/JCDE.JCDE_288_24.


Dual- or single rinse? The tubular sealer penetration of endodontic chelating agents.

Ozel B, Ayhan T, Kaptan F, Sahin F, Karapinar-Kazandag M PLoS One. 2024; 19(6):e0303377.

PMID: 38875249 PMC: 11178202. DOI: 10.1371/journal.pone.0303377.


An In Vitro Evaluation of the Antimicrobial Efficacy of a Novel Irrigant Using Next-Generation Sequencing.

Hackbarth M, Montoya M, Noblett W, Lima B, Dietz M, Staley C J Endod. 2024; 50(9):1314-1320.e1.

PMID: 38815857 PMC: 11402568. DOI: 10.1016/j.joen.2024.05.010.


Update on chelating agents in endodontic treatment: A systematic review.

Fortea L, Sanz-Serrano D, Luz L, Bardini G, Mercade M J Clin Exp Dent. 2024; 16(4):e516-e538.

PMID: 38725809 PMC: 11078497. DOI: 10.4317/jced.60989.