Delayed Presentation of Traumatic Dislocation of a Visian Implantable Collamer Lens

Overview
Journal J Refract Surg
Date 2012 Apr 21
PMID 22515178
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To report traumatic dislocation of a Visian Implantable Collamer Lens (ICL, STAAR Surgical Co) discovered on routine examination.

Methods: A 26-year-old man was found to have ICL subluxation into the anterior chamber with pupillary capture on routine screening examination. The patient reported being punched near the left eye 2 weeks earlier. He noted mild blurry vision, no pain, and uncorrected distance visual acuity (UDVA) was 20/30, which was decreased from his baseline of 20/20 in the affected eye.

Results: Surgical repositioning was performed under pupillary dilation without complication. Postoperatively, UDVA was 20/20(-2). Persistent pigment on the ICL, slight pupillary margin peaking, and anterior chamber inflammation were noted.

Conclusions: Traumatic ICL dislocation may occur with minimal signs and symptoms. Education of patients about the necessity for examination after ocular trauma and need to wear eye protection during activities at high risk of ocular trauma are important.

Citing Articles

Dislocation of implantable collamer phakic lens after blunt trauma.

Zhong X, Li T, Du Y, Zhang M Int J Ophthalmol. 2024; 17(11):2145-2147.

PMID: 39559322 PMC: 11528279. DOI: 10.18240/ijo.2024.11.22.


Spontaneous dislocation of a toric implantable collamer lens resulting in corneal endothelial decompensation: a case report and review of the literature.

Zhang L, Li Y, Lei C, Wang L, Zhang M Int J Ophthalmol. 2023; 16(1):135-138.

PMID: 36659942 PMC: 9815974. DOI: 10.18240/ijo.2023.01.20.


Dislocation of implantable collamer lens following blunt trauma.

Alsugayhi M, Husain O, Al-Swailem S Am J Ophthalmol Case Rep. 2022; 29:101768.

PMID: 36570105 PMC: 9772575. DOI: 10.1016/j.ajoc.2022.101768.


Multicenter survey on implantable collamer lens dislocation.

Kojima T, Kitazawa Y, Nakamura T, Kamiya K, Ichikawa K, Igarashi A PLoS One. 2022; 17(2):e0264015.

PMID: 35157743 PMC: 8843229. DOI: 10.1371/journal.pone.0264015.


Traumatic dislocation of an implantable phakic contact lens.

Kanaradi R, Bhuta N, Shetty N, Shetty R, Jayadev C Indian J Ophthalmol. 2020; 68(12):3072-3074.

PMID: 33229711 PMC: 7856936. DOI: 10.4103/ijo.IJO_2905_20.