Rationale And Objectives: Magnetic resonance elastography (MRE) images the propagation of mechanical shear waves in tissue and uses that information to generate quantitative measures of tissue stiffness. Hepatic MRE has been successfully performed in thousands of patients, with good correlation between histologic grade of fibrosis and tissue stiffness. There has been no prior investigation of the utility of MRE for the assessment of kidney transplants. The aims of this study were to prospectively evaluate the feasibility of MRE in a small group of kidney transplant recipients and to correlate the measured magnetic resonance elastographic stiffness values with biopsy-proven histopathologic fibrosis.

Materials And Methods: MRE of renal transplants was performed in 11 patients returning for protocol allograft biopsies. Calculated tissue stiffness values were compared to histologic degree of fibrosis in nine of the 11 patients.

Results: The mean stiffness of two patients with moderate interstitial fibrosis was higher than the mean of six patients with mild interstitial fibrosis, but not significantly so (90 Hz, P = .12; 120 Hz, P = .17; 150 Hz, P = .26). The mean stiffness of the two patients with moderate interstitial fibrosis was slightly greater than the mean of one patient with no significant interstitial fibrosis at 90 Hz (P = .78) and slightly less at 120 and 150 Hz (P = .88 and P = .76). The mean stiffness of the six patients with mild interstitial fibrosis did not differ significantly from that of the one patient with no interstitial fibrosis (90 Hz, P = .35; 120 Hz, P = .22; 150 Hz, P = .16).

Conclusions: Preliminary results demonstrate feasibility and support known multifactorial influences on renal stiffness.

Citing Articles

Prediction of allograft function in pre-transplant kidneys using sound touch elastography (STE): an ex vivo study.

Pan F, Yang D, Zhao G, Huang S, Wang Y, Xu M Insights Imaging. 2024; 15(1):245.

PMID: 39392520 PMC: 11469982. DOI: 10.1186/s13244-024-01837-y.


Investigating the role of ultrasound-based shear wave elastography in kidney transplanted patients: correlation between non-invasive fibrosis detection, kidney dysfunction and biopsy results-a systematic review and meta-analysis.

Filipov T, Teutsch B, Szabo A, Forintos A, Acs J, Varadi A J Nephrol. 2024; 37(6):1509-1522.

PMID: 38427308 PMC: 11473454. DOI: 10.1007/s40620-023-01856-w.


Magnetic resonance elastography resolving all gross anatomical segments of the kidney during controlled hydration.

Wolf M, Darwish O, Neji R, Eder M, Sunder-Plassmann G, Heinz G Front Physiol. 2024; 15:1327407.

PMID: 38384795 PMC: 10880033. DOI: 10.3389/fphys.2024.1327407.


Renal MRI: From Nephron to NMR Signal.

Bane O, Seeliger E, Cox E, Stabinska J, Bechler E, Lewis S J Magn Reson Imaging. 2023; 58(6):1660-1679.

PMID: 37243378 PMC: 11025392. DOI: 10.1002/jmri.28828.


Imaging fibrosis in pediatric kidney transplantation: A pilot study.

Elsingergy M, Viteri B, Otero H, Bhatti T, Morales T, Roberts T Pediatr Transplant. 2023; 27(5):e14540.

PMID: 37166372 PMC: 10824264. DOI: 10.1111/petr.14540.


References
1.
Sadowski E, Djamali A, Wentland A, Muehrer R, Becker B, Grist T . Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys. Magn Reson Imaging. 2009; 28(1):56-64. PMC: 2891158. DOI: 10.1016/j.mri.2009.05.044. View

2.
Yin M, Talwalkar J, Glaser K, Manduca A, Grimm R, Rossman P . Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterol Hepatol. 2007; 5(10):1207-1213.e2. PMC: 2276978. DOI: 10.1016/j.cgh.2007.06.012. View

3.
Blondin D, Lanzman R, Mathys C, Grotemeyer D, Voiculescu A, Sandmann W . [Functional MRI of transplanted kidneys using diffusion-weighted imaging]. Rofo. 2009; 181(12):1162-7. DOI: 10.1055/s-0028-1109511. View

4.
Thoeny H, Zumstein D, Simon-Zoula S, Eisenberger U, De Keyzer F, Hofmann L . Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. Radiology. 2006; 241(3):812-21. DOI: 10.1148/radiol.2413060103. View

5.
Patel M, Phillips C, Young S, Kriegshauser J, Chen F, Eversman W . US-guided renal transplant biopsy: efficacy of a cortical tangential approach. Radiology. 2010; 256(1):290-6. DOI: 10.1148/radiol.10091793. View