» Articles » PMID: 22484235

DNA Electrochemical Biosensor Based on Thionine-graphene Nanocomposite

Overview
Date 2012 Apr 10
PMID 22484235
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

A novel protocol for development of DNA electrochemical biosensor based on thionine-graphene nanocomposite modified gold electrode was presented. The thionine-graphene nanocomposite layer with highly conductive property was characterized by scanning electron microscopy, transmission electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. An amino-substituted oligonucleotide probe was covalently grafted onto the surface of the thionine-graphene nanocomposite by the cross-linker glutaraldehyde. The hybridization reaction on the modified electrode was monitored by differential pulse voltammetry analysis using an electroactive intercalator daunomycin as the indicator. Under optimum conditions, the proposed biosensor exhibited high sensitivity and low detection limit for detecting complementary oligonucleotide. The complementary oligonucleotide could be quantified in a wide range of 1.0 × 10(-12) to 1.0 × 10(-7)M with a good linearity (R(2)=0.9976) and a low detection limit of 1.26 × 10(-13)M (S/N=3). In addition, the biosensor was highly selective to discriminate one-base or two-base mismatched sequences.

Citing Articles

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane.

Jiang N, Shrotriya P Micromachines (Basel). 2025; 16(1).

PMID: 39858691 PMC: 11767673. DOI: 10.3390/mi16010035.


Detection of in dental plaque using a DNA biosensor for noninvasive diagnosis.

Chen L, Cui H, Fan S, Li Z, Han S, Ma X RSC Adv. 2022; 8(38):21075-21083.

PMID: 35539942 PMC: 9080877. DOI: 10.1039/c8ra03134g.


An ultrasensitive ratiometric immunosensor based on the ratios of conjugated distyrylbenzene derivative nanosheets with AIECL properties and electrochemical signal for CYFRA21-1 detection.

Lv X, Bi M, Xu X, Li Y, Geng C, Cui B Anal Bioanal Chem. 2021; 414(3):1389-1402.

PMID: 34741181 DOI: 10.1007/s00216-021-03764-z.


Development of a Label-Free Electrochemical Aptasensor for the Detection of Tau381 and its Preliminary Application in AD and Non-AD Patients' Sera.

Tao D, Shui B, Gu Y, Cheng J, Zhang W, Jaffrezic-Renault N Biosensors (Basel). 2019; 9(3).

PMID: 31262001 PMC: 6784373. DOI: 10.3390/bios9030084.


A Molecular Interaction Analysis Reveals the Possible Roles of Graphene Oxide in a Glucose Biosensor.

Sumaryada T, Sandy Gunawan M, Perdana S, Arjo S, Maddu A Biosensors (Basel). 2019; 9(1).

PMID: 30696069 PMC: 6468508. DOI: 10.3390/bios9010018.