» Articles » PMID: 22448249

In Vivo Imaging of Macrophages During the Early-stages of Abdominal Aortic Aneurysm Using High Resolution MRI in ApoE Mice

Overview
Journal PLoS One
Date 2012 Mar 27
PMID 22448249
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Angiotensin II (ANG II) promotes vascular inflammation and induces abdominal aortic aneurysm (AAA) in hyperlipidemic apolipoprotein E knock-out (apoE(-/-)) mice. The aim of the present study was to detect macrophage activities in an ANG II-induced early-stage AAA model using superparamagnetic iron oxide (SPIO) as a marker.

Methodology/principal Findings: Twenty-six male apoE(-/-) mice received saline or ANG II (1000 or 500 ng/kg/min) infusion for 14 days. All animals underwent MRI scanning following administration of SPIO with the exception of three mice in the 1000 ng ANG II group, which were scanned without SPIO administration. MR imaging was performed using black-blood T2 to proton density -weighted multi-spin multi-echo sequence. In vivo MRI measurement of SPIO uptake and abdominal aortic diameter were obtained. Prussian blue, CD68,α-SMC and MAC3 immunohistological stains were used for the detection of SPIO, macrophages and smooth muscle cells. ANG II infusion with 1000 ng/kg/min induced AAA in all of the apoE(-/-) mice. ANG II infusion exhibited significantly higher degrees of SPIO uptake, which was detected using MRI as a distinct loss of signal intensity. The contrast-to-noise ratio value decreased in proportion to an increase in the number of iron-laden macrophages in the aneurysm. The aneurysmal vessel wall in both groups of ANG II treated mice contained more iron-positive macrophages than saline-treated mice. However, the presence of cells capable of phagocytosing haemosiderin in mural thrombi also induced low-signal-intensities via MRI imaging.

Conclusions/significance: SPIO is taken up by macrophages in the shoulder and the outer layer of AAA. This alters the MRI signaling properties and can be used in imaging inflammation associated with AAA. It is important to compare images of the aorta before and after SPIO injection.

Citing Articles

Translating mouse models of abdominal aortic aneurysm to the translational needs of vascular surgery.

Busch A, Bleichert S, Ibrahim N, Wortmann M, Eckstein H, Brostjan C JVS Vasc Sci. 2021; 2:219-234.

PMID: 34778850 PMC: 8577080. DOI: 10.1016/j.jvssci.2021.01.002.


Nanoparticle-Assisted Diagnosis and Treatment for Abdominal Aortic Aneurysm.

Yin L, Zhang K, Sun Y, Liu Z Front Med (Lausanne). 2021; 8:665846.

PMID: 34307401 PMC: 8292633. DOI: 10.3389/fmed.2021.665846.


Early Detection of Aortic Degeneration in a Mouse Model of Sporadic Aortic Aneurysm and Dissection Using Nanoparticle Contrast-Enhanced Computed Tomography.

Ghaghada K, Ren P, Devkota L, Starosolski Z, Zhang C, Vela D Arterioscler Thromb Vasc Biol. 2021; 41(4):1534-1548.

PMID: 33535789 PMC: 7990703. DOI: 10.1161/ATVBAHA.120.315210.


Molecular MR-Imaging for Noninvasive Quantification of the Anti-Inflammatory Effect of Targeting Interleukin-1β in a Mouse Model of Aortic Aneurysm.

Brangsch J, Reimann C, Kaufmann J, Adams L, Onthank D, Thone-Reineke C Mol Imaging. 2020; 19:1536012120961875.

PMID: 33216687 PMC: 7682246. DOI: 10.1177/1536012120961875.


Ex vivo magnetic particle imaging of vascular inflammation in abdominal aortic aneurysm in a murine model.

Mangarova D, Brangsch J, Mohtashamdolatshahi A, Kosch O, Paysen H, Wiekhorst F Sci Rep. 2020; 10(1):12410.

PMID: 32709967 PMC: 7381631. DOI: 10.1038/s41598-020-69299-y.


References
1.
Turner G, Olzinski A, Bernard R, Aravindhan K, Karr H, Mirabile R . In vivo serial assessment of aortic aneurysm formation in apolipoprotein E-deficient mice via MRI. Circ Cardiovasc Imaging. 2009; 1(3):220-6. DOI: 10.1161/CIRCIMAGING.108.787358. View

2.
Swedenborg J, Mayranpaa M, Kovanen P . Mast cells: important players in the orchestrated pathogenesis of abdominal aortic aneurysms. Arterioscler Thromb Vasc Biol. 2011; 31(4):734-40. DOI: 10.1161/ATVBAHA.110.213157. View

3.
Chu B, Kampschulte A, Ferguson M, Kerwin W, Yarnykh V, OBrien K . Hemorrhage in the atherosclerotic carotid plaque: a high-resolution MRI study. Stroke. 2004; 35(5):1079-84. DOI: 10.1161/01.STR.0000125856.25309.86. View

4.
Pande A, Kohler R, Aikawa E, Weissleder R, Jaffer F . Detection of macrophage activity in atherosclerosis in vivo using multichannel, high-resolution laser scanning fluorescence microscopy. J Biomed Opt. 2006; 11(2):021009. DOI: 10.1117/1.2186337. View

5.
Sadat U, Taviani V, Patterson A, Young V, Graves M, Teng Z . Ultrasmall superparamagnetic iron oxide-enhanced magnetic resonance imaging of abdominal aortic aneurysms--a feasibility study. Eur J Vasc Endovasc Surg. 2010; 41(2):167-74. DOI: 10.1016/j.ejvs.2010.08.022. View