Corneal Haze Determined by Confocal Microscopy 2 Years After Descemet Stripping with Endothelial Keratoplasty for Fuchs Corneal Dystrophy

Overview
Journal Arch Ophthalmol
Specialty Ophthalmology
Date 2012 Mar 14
PMID 22410629
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To quantify corneal light scatter and its relationship to vision after Descemet stripping with endothelial keratoplasty (DSEK).

Methods: Eyes with Fuchs corneal dystrophy were examined before and 1, 3, 6, 12, and 24 months after DSEK. Outcome measures were high- and low-contrast visual acuity, contrast sensitivity, and forward light scatter. Corneal reflectivity (backscatter), expressed in scatter units (SU), was quantified using in vivo confocal microscopy.

Results: Comparing 49 study eyes with 35 normal eyes, the mean (SD) corneal subepithelial layer was more reflective than normal before (2325 [613] vs 1208 [287] SU, P<.001) and through 24 months after DSEK (1760 [432] SU, P<.001). Interface reflectivity remained higher than in normal stroma through 24 months (1228 [287] vs 827 [188] SU, P<.001). At 1 year, forward light scatter correlated with subepithelial reflectivity (r=0.28, P=.01) but not interface reflectivity. Recipient age was correlated with improvement in subepithelial reflectivity at 12 months (r=–0.41, P=.01, 34 eyes) and 24 months (r=–0.36, P=.02, 26 eyes) after DSEK, and the improvement of subepithelial haze in eyes of participants aged 62 years or younger was correlated with improvement in forward light scatter at 12 months (r=0.52, P=.008) and 24 months (r=0.62, P=.004).

Conclusions: In Fuchs corneal dystrophy, the corneal subepithelial region is a more important source of forward light scatter than the DSEK interface. Subepithelial haze improves more in younger patients and is associated with improvement in forward light scatter.

Clinical Relevance: Visual function after DSEK is affected by residual haze in the anterior host cornea more so than the surgical interface. Haze, which likely is experienced as glare disability, improves after surgical intervention but improves more in younger patients.

Citing Articles

Applications of Imaging Technologies in Fuchs Endothelial Corneal Dystrophy: A Narrative Literature Review.

Han S, Liu Y, Liu C, Mehta J Bioengineering (Basel). 2024; 11(3).

PMID: 38534545 PMC: 10968379. DOI: 10.3390/bioengineering11030271.


Effects of Descemet Stripping Automated Endothelial Keratoplasty on Corneal Densitometry of Cases with Long-Standing Pseudophakic Bullous Keratopathy.

Hashemian M, Latifi G, Cheraqpour K, Ghods S, Abdi P, Ghochani G J Curr Ophthalmol. 2024; 35(2):159-164.

PMID: 38250490 PMC: 10795814. DOI: 10.4103/joco.joco_70_22.


Optical quality of the cornea after Descemet membrane endothelial keratoplasty surgery: early results from Türkiye.

Karaca E, Isik F, Kemer O Korean J Transplant. 2023; 37(3):203-209.

PMID: 37694599 PMC: 10583968. DOI: 10.4285/kjt.23.0032.


RNA-Seq-based transcriptome analysis of corneal endothelial cells derived from patients with Fuchs endothelial corneal dystrophy.

Nakagawa T, Tokuda Y, Nakano M, Komori Y, Hanada N, Tourtas T Sci Rep. 2023; 13(1):8647.

PMID: 37244951 PMC: 10224979. DOI: 10.1038/s41598-023-35468-y.


Loss of Corneal Nerves and Corneal Haze in Patients with Fuchs' Endothelial Corneal Dystrophy with the Transcription Factor 4 Gene Trinucleotide Repeat Expansion.

Gillings M, Mastro A, Zhang X, Kiser K, Gu J, Xing C Ophthalmol Sci. 2022; 3(1):100214.

PMID: 36275201 PMC: 9563205. DOI: 10.1016/j.xops.2022.100214.