» Articles » PMID: 22408503

Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2012 Mar 13
PMID 22408503
Citations 71
Authors
Affiliations
Soon will be listed here.
Abstract

Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC) disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS), cavity ringdown spectroscopy (CRDS), integrated cavity output spectroscopy (ICOS), cavity enhanced absorption spectroscopy (CEAS), cavity leak-out spectroscopy (CALOS), photoacoustic spectroscopy (PAS), quartz-enhanced photoacoustic spectroscopy (QEPAS), and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS). Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

Citing Articles

Breath Test via Mid-Infrared Sensor Technology.

Flores Rangel G, Diaz de Leon Martinez L, Mizaikoff B ACS Sens. 2025; 10(2):1005-1010.

PMID: 39921651 PMC: 11877511. DOI: 10.1021/acssensors.4c02785.


Nitric Oxide Signaling and Sensing in Age-Related Diseases.

Mazuryk O, Gurgul I, Oszajca M, Polaczek J, Kieca K, Bieszczad-Zak E Antioxidants (Basel). 2024; 13(10).

PMID: 39456466 PMC: 11504650. DOI: 10.3390/antiox13101213.


Exhaled Breath Analysis: From Laboratory Test to Wearable Sensing.

Heng W, Yin S, Chen Y, Gao W IEEE Rev Biomed Eng. 2024; 18:50-73.

PMID: 39412981 PMC: 11875904. DOI: 10.1109/RBME.2024.3481360.


A comprehensive review on electromagnetic wave based non-invasive glucose monitoring in microwave frequencies.

Kandwal A, Sharma Y, Jasrotia R, Choon Kit C, Lakshmaiya N, Sillanpaa M Heliyon. 2024; 10(18):e37825.

PMID: 39323784 PMC: 11422007. DOI: 10.1016/j.heliyon.2024.e37825.


Ultratrace eNose Sensing of VOCs toward Breath Analysis Applications Utilizing an eNose-Based Analyzer.

Glockler J, Jaeschke C, Padilla M, Mitrovics J, Mizaikoff B ACS Meas Sci Au. 2024; 4(2):184-187.

PMID: 38645578 PMC: 11027196. DOI: 10.1021/acsmeasuresciau.3c00053.


References
1.
Lewicki R, Wysocki G, Kosterev A, Tittel F . QEPAS based detection of broadband absorbing molecules using a widely tunable, cw quantum cascade laser at 8.4 mum. Opt Express. 2009; 15(12):7357-66. DOI: 10.1364/oe.15.007357. View

2.
Hofstetter D, Beck M, Faist J, Nagele M, Sigrist M . Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers. Opt Lett. 2007; 26(12):887-9. DOI: 10.1364/ol.26.000887. View

3.
Diskin A, Spanel P, Smith D . Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days. Physiol Meas. 2003; 24(1):107-19. DOI: 10.1088/0967-3334/24/1/308. View

4.
Li P, Xu G, Wang C, Gong Y, He Y . Breath pentane: an indicator for early and continuous monitoring of lipid peroxidation in hepatic ischaemia-reperfusion injury. Eur J Anaesthesiol. 2009; 26(6):513-9. DOI: 10.1097/eja.0b013e328326f7b7. View

5.
Fried A, Drummond J, Henry B, Fox J . Versatile integrated tunable diode laser system for high precision: application for ambient measurements of OCS. Appl Opt. 2010; 30(15):1916-32. DOI: 10.1364/AO.30.001916. View