Purpose: To quantify liver T1 relaxation times before and after oxygen inhalation in patients with and without liver cirrhosis using a 3 Tesla (T) MRI.

Materials And Methods: Institutional Review Board approval and written informed consent were obtained. Ninety-two noncirrhotic patients and 87 patients with hepatitis B viral liver cirrhosis (72 Child-Pugh class A and 15 Child-Pugh class B or C) underwent MRI with a 3.0T system before and after the supply of 100% oxygen at a rate of 15 L/min by means of a nonrebreather ventilation mask for 3 min. T1 maps were acquired using three-dimensional spoiled gradient echo sequences with two different flip angles (2° and 14°) and a fixed TR/TE (2.54 ms/0.95 ms). Liver T1 values were obtained using a T1 processing tool (MapIT software). The mean baseline T1 values of three groups (control, Child-Pugh class A, and Child-Pugh class B/C) were compared using an analysis of variance test. Liver T1 value before and after oxygenation was compared using a paired t-test for each group.

Results: The baseline liver T1 value was significantly higher in the control group (941 ± 136 ms) than in Child-Pugh A (858 ± 143 ms) and Child-Pugh B/C (783 ± 164 ms) group (P < 0.001 and P < 0.0001). The reduction in the liver T1 value after oxygen inhalation was significant in the control group (P = 0.012) but not significant in Child-Pugh class A (P = 0.079) and Child-Pugh class B/C (P = 0.752).

Conclusion: The baseline liver T1 relaxation time was significantly different between the patients with and without liver cirrhosis. The shortening effect of oxygen on the liver T1 value was significant in the control group but not in the cirrhotic patients.

Citing Articles

Accelerated 2D radial Look-Locker T1 mapping using a deep learning-based rapid inversion recovery sampling technique.

Ahanonu E, Goerke U, Johnson K, Toner B, Martin D, Deshpande V NMR Biomed. 2024; 37(12):e5266.

PMID: 39358992 PMC: 11892465. DOI: 10.1002/nbm.5266.


Simultaneous Multiparameter Mapping of the Liver in a Single Breath-Hold or Respiratory-Triggered Acquisition Using Multi-Inversion Spin and Gradient Echo MRI.

Manhard M, Kilpattu Ramaniharan A, Tkach J, Trout A, Dillman J, Pednekar A J Magn Reson Imaging. 2024; 61(4):1925-1936.

PMID: 39192381 PMC: 11896940. DOI: 10.1002/jmri.29584.


Contrast-Enhanced Magnetic Resonance Imaging Based T1 Mapping and Extracellular Volume Fractions Are Associated with Peripheral Artery Disease.

Fitian A, Shieh M, Gimnich O, Belousova T, Taylor A, Ballantyne C J Cardiovasc Dev Dis. 2024; 11(6).

PMID: 38921681 PMC: 11203653. DOI: 10.3390/jcdd11060181.


MRI-compatible abdomen phantom to mimic respiratory-triggered organ movement while performing needle-based interventions.

Vogt I, Engel K, Schlunz A, Kowal R, Hensen B, Gutberlet M Int J Comput Assist Radiol Surg. 2024; 19(12):2329-2338.

PMID: 38839726 PMC: 11607006. DOI: 10.1007/s11548-024-03188-x.


Imaging of the Liver and Pancreas: The Added Value of MRI.

Morana G, Beleu A, Geraci L, Tomaiuolo L, Venturini S Diagnostics (Basel). 2024; 14(7).

PMID: 38611607 PMC: 11011374. DOI: 10.3390/diagnostics14070693.