» Articles » PMID: 22386376

Volumetric Modulation Arc Radiotherapy with Flattening Filter-free Beams Compared with Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: a Feasibility Study

Abstract

Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT).

Methods And Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving ≥ 95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving ≥ 5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics.

Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 ± 0.1 for RA and IMRT and 1.5 ± 0.2 for 3D-CRT. The mean lung dose was 12.2 ± 4.5 for IMRT, 11.3 ± 4.6 for RA, and 10.8 ± 4.4 for RA with FFF beams, 18.2 ± 8.5 for 3D-CRT. The percentage of volume receiving ≥ 20 Gy ranged from 23.6% ± 9.1% to 21.1% ± 9.7% for IMRT and RA (FFF beams) and 39.2% ± 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 ± 139, 322 ± 20, and 387 ± 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a ∼20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds).

Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

Citing Articles

A comprehensive Study of the Out of Field Non Target Dose Associated with 6 and 10 MV Flattened and Flattening Filter Free X Ray Beam in a True Beam Linear Accelerator.

Athiyaman H, Anbu G, Mayilvaganan A, Chougule A, Sharma N, Kumar H Asian Pac J Cancer Prev. 2024; 25(5):1529-1538.

PMID: 38809624 PMC: 11318832. DOI: 10.31557/APJCP.2024.25.5.1529.


Feasibility of flattening filter free beams for hippocampal avoidance whole-brain radiotherapy: a dosimetric and radiobiological analysis.

Liu F, Peng Y, Li Q, Zhang Q, Shi H, Qie S Front Oncol. 2023; 13:1290434.

PMID: 38074656 PMC: 10703487. DOI: 10.3389/fonc.2023.1290434.


Prediction of dose deposition matrix using voxel features driven machine learning approach.

Jiao S, Zhao X, Yao S Br J Radiol. 2023; 96(1145):20220373.

PMID: 36856129 PMC: 10161919. DOI: 10.1259/bjr.20220373.


Variability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study.

Yadav P, DesRosiers C, Mitra R, Srivastava S, Das I J Clin Med. 2023; 12(3).

PMID: 36769553 PMC: 9918128. DOI: 10.3390/jcm12030906.


Computed Tomography-Based Evaluation of Volume and Position Changes of the Target Region and Organs at Risk During Radiotherapy for Esophageal Cancer: A Pilot Study.

Liu Y, Peng Y, Li Q, Shen G, Ma Y, Chen M Front Oncol. 2021; 11:702400.

PMID: 34395275 PMC: 8355816. DOI: 10.3389/fonc.2021.702400.