» Articles » PMID: 22363863

Severe Hair Loss of the Scalp Due to a Hair Dye Containing Para Phenylenediamine

Overview
Journal ISRN Dermatol
Specialty Dermatology
Date 2012 Feb 25
PMID 22363863
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

We report the case of a 41-year-old female showing severe hair loss approximately 90% after the use of a hair dye. These symptoms developed six days after the use of a hair dye containing PPD. A patch test showed a (++) reaction at 48 h to 1% PPD in petrolatum, whereas all metals and white petrolatum were negative. She was therefore diagnosed with contact dermatitis due to PPD, resulting in hair loss. The skin lesions gradually improved after starting treatment with the systemic corticosteroids. The possibility that allergic contact dermatitis from hair dyes may be responsible for telogen effluvium should always be considered in a patient with increased hair loss.

Citing Articles

Changing human hair fibre colour and shape from the follicle.

Matama T, Costa C, Fernandes B, Araujo R, Cruz C, Tortosa F J Adv Res. 2023; 64:45-65.

PMID: 37967812 PMC: 11464751. DOI: 10.1016/j.jare.2023.11.013.


A Comprehensive Review of Mammalian Pigmentation: Paving the Way for Innovative Hair Colour-Changing Cosmetics.

Fernandes B, Cavaco-Paulo A, Matama T Biology (Basel). 2023; 12(2).

PMID: 36829566 PMC: 9953601. DOI: 10.3390/biology12020290.


Hair Dye Ingredients and Potential Health Risks from Exposure to Hair Dyeing.

He L, Michailidou F, Gahlon H, Zeng W Chem Res Toxicol. 2022; 35(6):901-915.

PMID: 35666914 PMC: 9214764. DOI: 10.1021/acs.chemrestox.1c00427.


[Allergic contact dermatitis of the scalp].

Koch L, Aberer W Hautarzt. 2017; 68(6):466-471.

PMID: 28396898 DOI: 10.1007/s00105-017-3975-7.


The clinical spectrum of reactions developed based on paraphenylenediamine hypersensitivity two pediatric cases.

Nacaroglu H, Yavuz S, Basman E, Bahceci S, Tasdemir M, Yigit O Postepy Dermatol Alergol. 2016; 32(5):393-5.

PMID: 26759549 PMC: 4692816. DOI: 10.5114/pdia.2015.52738.


References
1.
Sosted H, Agner T, Andersen K, Menne T . 55 cases of allergic reactions to hair dye: a descriptive, consumer complaint-based study. Contact Dermatitis. 2003; 47(5):299-303. DOI: 10.1034/j.1600-0536.2002.470508.x. View

2.
Tosti A, Piraccini B, Van Neste D . Telogen effluvium after allergic contact dermatitis of the scalp. Arch Dermatol. 2001; 137(2):187-90. View

3.
Schafer T, Bohler E, Ruhdorfer S, Weigl L, Wessner D, Filipiak B . Epidemiology of contact allergy in adults. Allergy. 2001; 56(12):1192-6. DOI: 10.1034/j.1398-9995.2001.00086.x. View

4.
Benezra C, Sigman C, Bagheri D, Helmes C, Maibach H . A systematic search for structure-activity relationships of skin sensitizers. II. Para-phenylenediamines. Semin Dermatol. 1989; 8(2):88-93. View

5.
Wachsmuth R, Wilkinson M . Loss of eyelashes after use of a tinting mascara containing PPD. Contact Dermatitis. 2006; 54(3):169-70. DOI: 10.1111/j.0105-1873.2005.0739b.x. View