Application of Human Stem Cell-derived Cardiomyocytes in Safety Pharmacology Requires Caution Beyond HERG
Overview
Authors
Affiliations
Human embryonic stem cell-derived cardiomyocytes (hESC-CM) have been proposed as a new model for safety pharmacology. So far, a thorough description of their basic electrophysiology and extensive testing, and mechanistic explanations, of their overall pro-arrhythmic ability is lacking. Under standardized conditions, we have evaluated the sensitivity of hESC-CM to proarrhythmic provocations by blockade of hERG and other channels. Using voltage patch clamp, some ion current densities (pA/pF) in hESC-CM were comparable to adult CM: I(Kr) (-12.5 ± 6.9), I(Ks) (0.65 ± 0.12), I(Na,peak) (-72 ± 21), I(Na,late) (-1.10 ± 0.36), and I(Ca,L) (-4.3 ± 0.6). I(f) density was larger (-10 ± 1.1) and I(K1) not existent or very small (-2.67 ± 0.3). The low I(K1) density was corroborated by low KCNJ2 mRNA levels. Effects of pro-arrhythmic compounds on action potential (AP) parameters and provocation of early afterdepolarizations (EADs) revealed that Chromanol293B (100 μmol/l) and Bay K8644 (1 μmol/l) both significantly prolonged APD(90). ATX-II (<1 μmol/l ) and BaCl(2) (10 μmol/l ) had no effect on APD. The only compound that triggered EADs was hERG blocker Cisapride. Computer simulations and AP clamp showed that the immature AP of hESC-CM prevents proper functioning of I(Na)-channels, and result in lower peak/maximal currents of several other channels, compared to the adult situation. Lack of functional I(K1) channels and shifted I(Na) channel activation cause a rather immature electrophysiological phenotype in hESC-CM, and thereby limits the potential of this model to respond accurately to pro-arrhythmic triggers other than hERG block. Maturation of the electrical phenotype is a prerequiste for future implementation of the model in arrhythmogenic safety testing.
Dong Y, Liu F Int J Mol Sci. 2025; 25(24.
PMID: 39769159 PMC: 11677627. DOI: 10.3390/ijms252413396.
Recording ten-fold larger I conductances with automated patch clamping using equimolar Cs solutions.
Bloothooft M, Verbruggen B, Seibertz F, van der Heyden M, Voigt N, de Boer T Front Physiol. 2024; 15:1298340.
PMID: 38328302 PMC: 10847579. DOI: 10.3389/fphys.2024.1298340.
Butler A, Ascione R, Marrion N, Harmer S, Hancox J Sci Rep. 2024; 14(1):3185.
PMID: 38326449 PMC: 10850090. DOI: 10.1038/s41598-024-53571-6.
Clark A, Clerx M, Wei S, Lei C, de Boer T, Mirams G Europace. 2023; 25(9).
PMID: 37552789 PMC: 10445319. DOI: 10.1093/europace/euad243.
Dark N, Cosson M, Tsansizi L, Owen T, Ferraro E, Francis A Cell Rep Methods. 2023; 3(4):100456.
PMID: 37159667 PMC: 10163040. DOI: 10.1016/j.crmeth.2023.100456.