Purpose: We investigated factors affecting imaging of spectral-domain optical coherence tomography (SD-OCT) in gas-filled eyes after macular-hole (MH) surgery.

Methods: The study comprised 25 eyes in 23 patients, eight men and 15 women, with a mean age of 66.9 (48-77) years, all of whom had undergone vitrectomy for MH. Sulfur hexafluoride (SF(6)) gas was used as a tamponade, and the patients were maintained in a prone position after surgery. The SD-OCT imaging was performed on postoperative days 1 and 2.

Results: The success rate of imaging was 88.0% (22/25 eyes) on postoperative day 1 and 95.8% (23/24 eyes) on postoperative day 2. The rate of MH closure in successful imaging cases was 81.8% (18 eyes) on postoperative day 1 and 95.7% (22 eyes) on postoperative day 2. The imaging accuracy in gas-filled eyes increased by setting the focus value of the OCT to a myopic refractive shift.

Conclusion: The imaging of many gas-filled eyes following MH surgery is possible, even at the early postoperative stage, by setting the focus value of the OCT to a myopic refractive shift.

Citing Articles

Intraoperative optical coherence tomography in macula involving rhegmatogenous retinal detachment repair with pars plana vitrectomy and perfluoron.

Toygar O, Riemann C Eye (Lond). 2015; 30(1):23-30.

PMID: 26656086 PMC: 4709554. DOI: 10.1038/eye.2015.230.

References
1.
Mittra R, Kim J, Han D, Pollack J . Sustained postoperative face-down positioning is unnecessary for successful macular hole surgery. Br J Ophthalmol. 2009; 93(5):664-6. DOI: 10.1136/bjo.2008.148544. View

2.
Sato Y, Isomae T . Macular hole surgery with internal limiting membrane removal, air tamponade, and 1-day prone positioning. Jpn J Ophthalmol. 2003; 47(5):503-6. DOI: 10.1016/s0021-5155(03)00103-5. View

3.
Tornambe P, Poliner L, Grote K . Macular hole surgery without face-down positioning. A pilot study. Retina. 1997; 17(3):179-85. DOI: 10.1097/00006982-199705000-00001. View

4.
Carvounis P, Kopel A, Kuhl D, Heffez J, Pepple K, Holz E . 25-gauge vitrectomy using sulfur hexafluoride and no prone positioning for repair of macular holes. Retina. 2009; 28(9):1188-92. DOI: 10.1097/IAE.0b013e318177f9a8. View

5.
Ciulla T, Frederick Jr A, Kelly C, Amrein R . Postvitrectomy positioning complicated by ulnar nerve palsy. Am J Ophthalmol. 1996; 122(5):739-40. DOI: 10.1016/s0002-9394(14)70500-8. View