Transducer-based Comparisons of the Prosthetic Feet Used by Transtibial Amputees for Different Walking Activities: a Pilot Study

Overview
Publisher Wolters Kluwer
Date 2012 Feb 21
PMID 22344316
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Knowledge of transtibial residual limb force and moment loading during gait can be clinically useful. The research question was whether a transducer attached between the socket and pylon can be used to detect differences in loading patterns created by prosthetic feet of different design and different walking activities in real-world environments outside the gait lab.

Objectives: To develop methods for obtaining, processing, analyzing and interpreting transducer measurements and examining their clinical usefulness.

Study Design: Case series design.

Methods: A convenience sample of four K3-K4 transtibial amputees and a wireless tri-axial transducer mounted distal to the socket. Activities included self-selected comfortable speed walking, and ascending and descending ramps and steps. Measurements taken about three orthogonal axes were processed to produce plots of normalized resultant force versus normalized resultant moment. Within-subject differences in peak resultant forces and moments were tested.

Results: Loading patterns between feet and subjects and among the activities were distinctly different. Optimal loading of peak resultant forces tentatively might occur around 25% and 69% to73% of stance during self-selected comfortable walking. Ascending and descending ramps is useful for examining heel and forefoot response.

Conclusions: Force-moment plots obtained from transducer data may assist clinical decision making.

Clinical Relevance: A pylon-mounted transducer distal to the socket reveals the moments and forces transmitted to the residual limb and can be used to evaluate the loading patterns on the residual limb associated with different foot designs and different everyday activities outside the gait lab.

Citing Articles

Advances in the measurement of prosthetic socket interface mechanics: a review of technology, techniques, and a 20-year update.

Young P, Hebert J, Marasco P, Carey J, Schofield J Expert Rev Med Devices. 2023; 20(9):729-739.

PMID: 37537898 PMC: 10581694. DOI: 10.1080/17434440.2023.2244418.


Loading applied on osseointegrated implant by transtibial bone-anchored prostheses during daily activities: Preliminary characterization of prosthetic feet.

Frossard L, Leech B, Pitkin M J Prosthet Orthot. 2020; 32(4):258-271.

PMID: 33013144 PMC: 7526518. DOI: 10.1097/jpo.0000000000000280.


Inter-participant variability data in loading applied on osseointegrated implant by transtibial bone-anchored prostheses during daily activities.

Frossard L, Leech B, Pitkin M Data Brief. 2019; 26:104510.

PMID: 31667273 PMC: 6811920. DOI: 10.1016/j.dib.2019.104510.


Inter-participant variability data in characterization of anthropomorphicity of prosthetic feet fitted to bone-anchored transtibial prosthesis.

Frossard L, Leech B, Pitkin M Data Brief. 2019; 25:104195.

PMID: 31406899 PMC: 6685672. DOI: 10.1016/j.dib.2019.104195.


Automated characterization of anthropomorphicity of prosthetic feet fitted to bone-anchored transtibial prosthesis.

Frossard L, Leech B, Pitkin M IEEE Trans Biomed Eng. 2019; .

PMID: 30872221 PMC: 6926161. DOI: 10.1109/TBME.2019.2904713.