A Device for Automatically Measuring and Supervising the Critical Care Patient's Urine Output

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2012 Feb 9
PMID 22315578
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Critical care units are equipped with commercial monitoring devices capable of sensing patients' physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units' healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale's pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient's bed, and guarantees that the urine flows properly through the urine meter input tube. The scale's readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.

Citing Articles

Systematic Review of Automated Diuresis Measurement in Critically Ill Patients.

Lafuente J, Gonzalez S, Gomez-Tello V, Puertas E, Aviles E, Beunza J Med Devices (Auckl). 2023; 16:251-259.

PMID: 38084350 PMC: 10710779. DOI: 10.2147/MDER.S428379.


Development of a urinometer for automatic measurement of urine flow in catheterized patients.

Lafuente J, Gonzalez S, Puertas E, Gomez-Tello V, Aviles E, Albo N PLoS One. 2023; 18(8):e0290319.

PMID: 37651353 PMC: 10470914. DOI: 10.1371/journal.pone.0290319.


Research of System Design and Automatic Detection Method for Excretion Nursing Equipment.

Hu B, Chen Z, Chen X, Lu S, Su Y, Yu H Healthcare (Basel). 2023; 11(3).

PMID: 36766962 PMC: 9914074. DOI: 10.3390/healthcare11030388.


Automated versus manual urine output monitoring in the intensive care unit.

Minor J, Smith A, Deutsch F, Kellum J Sci Rep. 2021; 11(1):17429.

PMID: 34465821 PMC: 8408210. DOI: 10.1038/s41598-021-97026-8.


Silicone Oil Decreases Biofilm Formation in a Capacitance-Based Automatic Urine Measurement System.

Slettengren M, Linnros M, van der Linden J Sensors (Basel). 2021; 21(2).

PMID: 33435177 PMC: 7826702. DOI: 10.3390/s21020445.


References
1.
Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B . Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2002; 345(19):1368-77. DOI: 10.1056/NEJMoa010307. View

2.
Klenzak J, Himmelfarb J . Sepsis and the kidney. Crit Care Clin. 2005; 21(2):211-22. DOI: 10.1016/j.ccc.2005.01.002. View

3.
Hersch M, Einav S, Izbicki G . Accuracy and ease of use of a novel electronic urine output monitoring device compared with standard manual urinometer in the intensive care unit. J Crit Care. 2009; 24(4):629.e13-7. DOI: 10.1016/j.jcrc.2008.12.008. View

4.
Schrier R, Wang W . Acute renal failure and sepsis. N Engl J Med. 2004; 351(2):159-69. DOI: 10.1056/NEJMra032401. View

5.
Otero A, Felix P, Barro S, Palacios F . Addressing the flaws of current critical alarms: a fuzzy constraint satisfaction approach. Artif Intell Med. 2009; 47(3):219-38. DOI: 10.1016/j.artmed.2009.08.002. View