» Articles » PMID: 22302715

Defining a Polymethine Dye for Fluorescence Anisotropy Applications in the Near-infrared Spectral Range

Overview
Journal Chemphyschem
Specialty Chemistry
Date 2012 Feb 4
PMID 22302715
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Fluorescence anisotropy in the near-infrared (NIR) spectral range is challenging because of the lack of appropriate NIR fluorescent labels. We have evaluated polymethine fluorescent dyes to identify a leading candidate for NIR anisotropy applications. The NIR dye LS601 demonstrated low fluorescence anisotropy values (r) as a result of its relatively long fluorescent lifetime 1.3 ns. The r value of LS601 unbound and coupled to biological macromolecules was found to have a sufficient dynamic range from 0.24 to 0.37, demonstrating the feasibility of fluorescence anisotropy in the NIR. The viability of fluorescence anisotropy using a NIR label was demonstrated by characterization of dye-protein conjugates. These results open the door to a number of applications in drug discovery, fluorescence anisotropy imaging and contrast agent development.

Citing Articles

Solvent Polarity Dependent Ultrafast Relaxation Kinetics of ADS800AT Dye.

Ponnan S, Rao D, Naraharisetty S J Fluoresc. 2024; .

PMID: 39320629 DOI: 10.1007/s10895-024-03932-1.


PEGylated peptide to TIP1 is a novel targeting agent that binds specifically to various cancers in vivo.

Kapoor V, Singh A, Rogers B, Thotala D, Hallahan D J Control Release. 2019; 298:194-201.

PMID: 30763622 PMC: 6557269. DOI: 10.1016/j.jconrel.2019.02.008.


Cell-free measurements of brightness of fluorescently labeled antibodies.

Zhou H, Tourkakis G, Shi D, Kim D, Zhang H, Du T Sci Rep. 2017; 7:41819.

PMID: 28150730 PMC: 5288790. DOI: 10.1038/srep41819.


Imaging of radicals following injury or acute stress in peripheral nerves with activatable fluorescent probes.

Zhou H, Yan Y, Ee X, Hunter D, Akers W, Wood M Free Radic Biol Med. 2016; 101:85-92.

PMID: 27693326 PMC: 5154790. DOI: 10.1016/j.freeradbiomed.2016.09.028.


Nanothermometry: From Microscopy to Thermal Treatments.

Zhou H, Sharma M, Berezin O, Zuckerman D, Berezin M Chemphyschem. 2015; 17(1):27-36.

PMID: 26443335 PMC: 7396319. DOI: 10.1002/cphc.201500753.


References
1.
Davey A, Walvick R, Liu Y, Heikal A, Sheets E . Membrane order and molecular dynamics associated with IgE receptor cross-linking in mast cells. Biophys J. 2006; 92(1):343-55. PMC: 1697873. DOI: 10.1529/biophysj.106.088815. View

2.
Pope , Haupts , Moore . Homogeneous fluorescence readouts for miniaturized high-throughput screening: theory and practice. Drug Discov Today. 1999; 4(8):350-362. DOI: 10.1016/s1359-6446(99)01340-9. View

3.
Levine L, Michener M, TOTH M, Holwerda B . Measurement of specific protease activity utilizing fluorescence polarization. Anal Biochem. 1997; 247(1):83-8. DOI: 10.1006/abio.1997.2047. View

4.
Rusinova E, Tretyachenko-Ladokhina V, Vele O, Senear D, Ross J . Alexa and Oregon Green dyes as fluorescence anisotropy probes for measuring protein-protein and protein-nucleic acid interactions. Anal Biochem. 2002; 308(1):18-25. DOI: 10.1016/s0003-2697(02)00325-1. View

5.
Levine B, Martinez T . Isomerization through conical intersections. Annu Rev Phys Chem. 2007; 58:613-34. DOI: 10.1146/annurev.physchem.57.032905.104612. View