The capabilities of a high-resolution (HR), accurate mass spectrometer (Exactive-MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50,000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive-MS was compared with that of a triple quadrupole mass spectrometer (TQ-MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole-N-oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR-MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR-MS offers several benefits over TQ-MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR-MS delivers comparable results to TQ-MS in routine quantitative drug analyses. Considering the advantages of HR-MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed.

Citing Articles

Flavonoids from sour jujube leaves: Ultrasound-assisted extraction, UPLC-QQQ-MS/MS quantification, and ameliorative effect on DSS-induced ulcerative colitis in mice.

Wei H, Wang X, Wang J, Ren S, Mur L, Lu D Ultrason Sonochem. 2025; 114:107279.

PMID: 39978127 PMC: 11889573. DOI: 10.1016/j.ultsonch.2025.107279.


Non-Targeted PFAS Suspect Screening and Quantification of Drinking Water Samples Collected through Community Engaged Research in North Carolina's Cape Fear River Basin.

Weed R, Campbell G, Brown L, May K, Sargent D, Sutton E Toxics. 2024; 12(6).

PMID: 38922083 PMC: 11209479. DOI: 10.3390/toxics12060403.


Advancing posaconazole quantification analysis with a new reverse-phase HPLC method in its bulk and marketed dosage form.

Rama A, Govindan I, Hebbar S, Chaturvedi A, Rani U, Naha A F1000Res. 2023; 12:468.

PMID: 37396051 PMC: 10314186. DOI: 10.12688/f1000research.132841.2.


Simultaneous quantification of all B vitamins and selected biosynthetic precursors in seawater and bacteria by means of different mass spectrometric approaches.

Bruns S, Wienhausen G, Scholz-Bottcher B, Wilkes H Anal Bioanal Chem. 2022; 414(27):7839-7854.

PMID: 36195729 PMC: 9568461. DOI: 10.1007/s00216-022-04317-8.


Identification and Quantification of Urinary Microbial Phenolic Metabolites by HPLC-ESI-LTQ-Orbitrap-HRMS and Their Relationship with Dietary Polyphenols in Adolescents.

Laveriano-Santos E, Marhuenda-Munoz M, Vallverdu-Queralt A, Martinez-Huelamo M, Tresserra-Rimbau A, Miliarakis E Antioxidants (Basel). 2022; 11(6).

PMID: 35740067 PMC: 9220091. DOI: 10.3390/antiox11061167.