Gareb B, van Bakelen N, Vissink A, Bos R, van Minnen B
Polymers (Basel). 2022; 14(14).
PMID: 35890557
PMC: 9316877.
DOI: 10.3390/polym14142782.
Dargusch M, Balasubramani N, Yang N, Johnston S, Ali Y, Wang G
Bioact Mater. 2022; 12:85-96.
PMID: 35087965
PMC: 8777300.
DOI: 10.1016/j.bioactmat.2021.10.026.
Ngo H, Bai Y, Sha J, Ishizuka S, Toda E, Osako R
Materials (Basel). 2022; 15(1).
PMID: 35009297
PMC: 8746248.
DOI: 10.3390/ma15010150.
Gareb B, van Bakelen N, Dijkstra P, Vissink A, Bos R, van Minnen B
Eur J Oral Sci. 2021; 129(5):e12800.
PMID: 34131965
PMC: 8596673.
DOI: 10.1111/eos.12800.
da Silva B, Souto-Souza D, de Souza G, Magesty R, de Cassia Avila B, Galvao E
Oral Maxillofac Surg. 2021; 25(3):289-301.
PMID: 33398647
DOI: 10.1007/s10006-020-00937-5.
Comparison of the mechanical properties of biodegradable and titanium osteosynthesis systems used in oral and maxillofacial surgery.
Gareb B, Roossien C, van Bakelen N, Verkerke G, Vissink A, Bos R
Sci Rep. 2020; 10(1):18143.
PMID: 33097757
PMC: 7584639.
DOI: 10.1038/s41598-020-75299-9.
Efficacy of bioresorbable plates in the osteosynthesis of linear mandibular fractures.
Arya S, Bhatt K, Bhutia O, Roychoudhury A
Natl J Maxillofac Surg. 2020; 11(1):98-105.
PMID: 33041585
PMC: 7518487.
DOI: 10.4103/njms.NJMS_54_19.
Bioabsorbable Osteofixation Materials for Maxillofacial Bone Surgery: A Review on Polymers and Magnesium-Based Materials.
On S, Cho S, Byun S, Yang B
Biomedicines. 2020; 8(9).
PMID: 32825692
PMC: 7555479.
DOI: 10.3390/biomedicines8090300.
Resorbable Implants for Mandibular Fracture Fixation: A Systematic Review and Meta-Analysis.
Chocron Y, Azzi A, Cugno S
Plast Reconstr Surg Glob Open. 2019; 7(8):e2384.
PMID: 31592391
PMC: 6756660.
DOI: 10.1097/GOX.0000000000002384.
Evaluation of one-point fixation for zygomaticomaxillary complex fractures using a three-dimensional photogrammetric analysis.
Kim S, Nam S, Park E, Kim Y
J Otolaryngol Head Neck Surg. 2019; 48(1):36.
PMID: 31362786
PMC: 6668153.
DOI: 10.1186/s40463-019-0359-2.
Overview of innovative advances in bioresorbable plate systems for oral and maxillofacial surgery.
Kanno T, Sukegawa S, Furuki Y, Nariai Y, Sekine J
Jpn Dent Sci Rev. 2018; 54(3):127-138.
PMID: 30128060
PMC: 6094489.
DOI: 10.1016/j.jdsr.2018.03.003.
Complications of a poly-L-lactic acid and polyglycolic acid osteosynthesis device for internal fixation in maxillofacial surgery.
Sukegawa S, Kanno T, Matsumoto K, Sukegawa-Takahashi Y, Masui M, Furuki Y
Odontology. 2018; 106(4):360-368.
PMID: 29417376
DOI: 10.1007/s10266-018-0345-6.
Resorbable versus titanium plates for orthognathic surgery.
Agnihotry A, Fedorowicz Z, Nasser M, Gill K
Cochrane Database Syst Rev. 2017; 10:CD006204.
PMID: 28977689
PMC: 6485457.
DOI: 10.1002/14651858.CD006204.pub3.
Biodegradable Materials for Bone Repair and Tissue Engineering Applications.
Sheikh Z, Najeeb S, Khurshid Z, Verma V, Rashid H, Glogauer M
Materials (Basel). 2017; 8(9):5744-5794.
PMID: 28793533
PMC: 5512653.
DOI: 10.3390/ma8095273.
Biomechanical Loading Evaluation of Unsintered Hydroxyapatite/poly-l-lactide Plate System in Bilateral Sagittal Split Ramus Osteotomy.
Sukegawa S, Kanno T, Manabe Y, Matsumoto K, Sukegawa-Takahashi Y, Masui M
Materials (Basel). 2017; 10(7).
PMID: 28773126
PMC: 5551807.
DOI: 10.3390/ma10070764.
Use of the bioactive resorbable plate system for zygoma and zygomatic arch replacement and fixation with modified Crockett's method for maxillectomy: A technical note.
Sukegawa S, Kanno T, Shibata A, Matsumoto K, Sukegawa-Takahashi Y, Sakaida K
Mol Clin Oncol. 2017; 7(1):47-50.
PMID: 28685074
PMC: 5492772.
DOI: 10.3892/mco.2017.1269.
Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial.
Gareb B, Van Bakelen N, Buijs G, Jansma J, de Visscher J, Hoppenreijs T
PLoS One. 2017; 12(5):e0177152.
PMID: 28493922
PMC: 5426637.
DOI: 10.1371/journal.pone.0177152.
The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis?.
Sukegawa S, Kanno T, Nagano D, Shibata A, Sukegawa-Takahashi Y, Furuki Y
J Craniofac Surg. 2016; 27(8):2124-2129.
PMID: 28005767
PMC: 5110331.
DOI: 10.1097/SCS.0000000000003147.
Cost-Effectiveness of a Biodegradable Compared to a Titanium Fixation System in Maxillofacial Surgery: A Multicenter Randomized Controlled Trial.
Van Bakelen N, Vermeulen K, Buijs G, Jansma J, de Visscher J, Hoppenreijs T
PLoS One. 2015; 10(7):e0130330.
PMID: 26192813
PMC: 4507946.
DOI: 10.1371/journal.pone.0130330.
Evaluation of the rigidity of sagittal split ramus osteotomy fixation using four designs of biodegradable and titanium plates--a numerical study.
Albougha S, Albogha M, Darwich M, Darwich K
Oral Maxillofac Surg. 2015; 19(3):281-5.
PMID: 25784154
DOI: 10.1007/s10006-015-0491-8.