» Articles » PMID: 22254352

Multiplexed, Rapid Point of Care Platform to Quantify Allergen-specific IgE

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Variation of probe immobilization on microarrays hinders the ability to make high quality, assertive and statistically relevant conclusions needed in the healthcare setting. To address this problem, we have developed a calibrated, compact, inexpensive, multiplexed, dual modality point-of-care detection platform that calibrates and correlates surface probe density measured label-free to captured labeled secondary antibody, is independent of chip-to-chip variability, and improves upon existing diagnostic technology. We have identified four major technological advantages of our proposed platform: the capability to perform single spot analysis based on the fluorophore used for detection, a 10-fold gain in fluorescence signal due to optimized substrate, a calibrated, quantitative method that uses the combined fluorescent and label-free modalities to accurately measure the density of probe and bound target for a variety of systems, and a compact measurement platform offering reliable and rapid results at the doctor's office. Already, we have formulated over a 90% linear correlation between the amount of probe bound to surface and the resulting fluorescence of captured target for IgG, β-lactoglobulin, Ara h 1 peanut allergen, and Phl 5a Timothy grass allergen.

References
1.
Schabacker D, Stefanovska I, Gavin I, Pedrak C, Chandler D . Protein array staining methods for undefined protein content, manufacturing quality control, and performance validation. Anal Biochem. 2006; 359(1):84-93. DOI: 10.1016/j.ab.2006.08.035. View

2.
Hessner M, Singh V, Wang X, Khan S, Tschannen M, Zahrt T . Utilization of a labeled tracking oligonucleotide for visualization and quality control of spotted 70-mer arrays. BMC Genomics. 2004; 5(1):12. PMC: 362869. DOI: 10.1186/1471-2164-5-12. View

3.
Cretich M, Di Carlo G, Longhi R, Gotti C, Spinella N, Coffa S . High sensitivity protein assays on microarray silicon slides. Anal Chem. 2009; 81(13):5197-203. DOI: 10.1021/ac900658c. View

4.
Shi L, Jones W, Jensen R, Harris S, Perkins R, Goodsaid F . The balance of reproducibility, sensitivity, and specificity of lists of differentially expressed genes in microarray studies. BMC Bioinformatics. 2008; 9 Suppl 9:S10. PMC: 2537561. DOI: 10.1186/1471-2105-9-S9-S10. View

5.
Diehl F, Grahlmann S, Beier M, Hoheisel J . Manufacturing DNA microarrays of high spot homogeneity and reduced background signal. Nucleic Acids Res. 2001; 29(7):E38. PMC: 31299. DOI: 10.1093/nar/29.7.e38. View