Abstract

In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given a great deal of attention by radiologists, referring physicians, technologists, and physicists. Dose-saving strategies are continuously evolving in terms of imaging techniques as well as dose management. Consequently, regular updates of this issue are necessary especially for radiologists who play a pivotal role in this activity. This review article will provide an update on how we can optimize CT dose in order to maximize the benefit-to-risk ratio of this clinically useful diagnostic imaging method.

Citing Articles

Computed tomography for major aortopulmonary collateral arteries: a roadmap to unifocalized pulmonary arterial flow.

Goo H Pediatr Radiol. 2025; .

PMID: 40063263 DOI: 10.1007/s00247-025-06202-9.


Achieving low radiation dose and contrast agents dose in coronary CT angiography at 60-kVp ultra-low tube voltage.

He W, Huang F, Wu X, Xie A, Sun W, Liu P BMC Med Imaging. 2025; 25(1):73.

PMID: 40038586 PMC: 11877812. DOI: 10.1186/s12880-025-01608-1.


Visualization of X-ray fields, overlaps, and over-beaming on surface of the head in spiral computed tomography using computer-aided design-based X-ray beam modeling.

Fukuda A, Ichikawa N, Hayashi T, Hirosawa A, Matsubara K Radiol Phys Technol. 2024; 18(1):287-292.

PMID: 39419861 DOI: 10.1007/s12194-024-00849-z.


Comparison of doses received from non-contrast enhanced brain CT examinations between two CT scanners.

Zatkuliakova V, Stevik M, Vorcak M, Sykora J, Trabalkova Z, Broocks G Heliyon. 2024; 10(17):e37043.

PMID: 39295996 PMC: 11408143. DOI: 10.1016/j.heliyon.2024.e37043.


Optimization of Fast Non-Local Means Noise Reduction Algorithm Parameter in Computed Tomographic Phantom Images Using 3D Printing Technology.

Kim H, Lim S, Park M, Kim K, Kang S, Lee Y Diagnostics (Basel). 2024; 14(15).

PMID: 39125465 PMC: 11312005. DOI: 10.3390/diagnostics14151589.


References
1.
Mettler Jr F, Bhargavan M, Faulkner K, Gilley D, Gray J, Ibbott G . Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources--1950-2007. Radiology. 2009; 253(2):520-31. DOI: 10.1148/radiol.2532082010. View

2.
Boone J, Geraghty E, Seibert J, Wootton-Gorges S . Dose reduction in pediatric CT: a rational approach. Radiology. 2003; 228(2):352-60. DOI: 10.1148/radiol.2282020471. View

3.
Kalender W, Buchenau S, Deak P, Kellermeier M, Langner O, van Straten M . Technical approaches to the optimisation of CT. Phys Med. 2008; 24(2):71-9. DOI: 10.1016/j.ejmp.2008.01.012. View

4.
Kalra M, Dang P, Singh S, Saini S, Shepard J . In-plane shielding for CT: effect of off-centering, automatic exposure control and shield-to-surface distance. Korean J Radiol. 2009; 10(2):156-63. PMC: 2651436. DOI: 10.3348/kjr.2009.10.2.156. View

5.
Yu L, Li H, Fletcher J, McCollough C . Automatic selection of tube potential for radiation dose reduction in CT: a general strategy. Med Phys. 2010; 37(1):234-43. DOI: 10.1118/1.3264614. View