» Articles » PMID: 22189029

Dosimetric Implications of Residual Seminal Vesicle Motion in Fiducial-guided Intensity-modulated Radiotherapy for Prostate Cancer

Overview
Journal Med Dosim
Specialty Radiology
Date 2011 Dec 23
PMID 22189029
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

To determine whether residual interfraction seminal vesicle (SV) displacement necessitates specific planning target volume (PTV) margins during fiducial-guided intensity modulated radiation therapy (IMRT) of the prostate. A planning computed tomography (CT) scan and 2 subsequent CT scans were prospectively obtained for 20 prostate cancer patients with intraprostatic fiducial markers. After CT registration, SV displacement relative to the prostate was quantified as a function of margin size for both the proximal (1 cm) SV (PSV) and the full SV (FSV). Two IMRT plans were simulated for each patient (prostate + PSV and prostate + FSV) both with a uniform 5-mm PTV margin. Minimum clinical target volume (CTV) dose (D(min)) and the volume of SV receiving 95% of the prescription dose (V(95%)) were assessed during treatment and compared with the initial plan. In all cases, SV displacement with respect to the prostate was greater for the FSV compared with the PSV. To ensure at least 95% geometrical coverage of the CTV for 90% of patients, margins of 5 and 8 mm were required for the PSV and FSV, respectively. Dosimetrically, residual SV displacement had minimal impact on PSV coverage compared with FSV coverage. For the PSV D(min) was ≥95% of the prescribed dose in 90% of patients with an overall mean V(95%) of 99.6 ± 0.8%; for the FSV D(min) was ≥95% of the prescribed dose in only 45% of patients with a mean V(95%) of 97.9 ± 2.4%. The SVs move differentially from the prostate and exhibit greater variation with increasing distance from the prostate. For plans targeting just the prostate and PSVs, 5-mm PTV expansions are adequate. However, despite daily localization of the prostate, larger PTV margins are required for cases where the intent is to completely cover the FSV.

Citing Articles

First-in-Men Online Adaptive Robotic Stereotactic Body Radiation Therapy: Toward Ultrahypofractionation for High-Risk Prostate Cancer Patients.

Brand V, Milder M, Christianen M, de Vries K, Hoogeman M, Incrocci L Adv Radiat Oncol. 2025; 10(2):101701.

PMID: 39866592 PMC: 11758839. DOI: 10.1016/j.adro.2024.101701.


Ultrahypofractionated Radiation Therapy for Prostate Cancer Including Seminal Vesicles in the Target Volume: A Treatment-planning Study Based on the HYPO-RT-PC Fractionation Schedule.

Wieslander E, Johannesson V, Nilsson P, Kjellen E, Gunnlaugsson A Adv Radiat Oncol. 2024; 9(7):101531.

PMID: 38883997 PMC: 11176962. DOI: 10.1016/j.adro.2024.101531.


Magnetic resonance imaging-guided radiotherapy for intermediate- and high-risk prostate cancer: Trade-off between planning target volume margin and online plan adaption.

Tetar S, Bruynzeel A, Verweij L, Bohoudi O, Slotman B, Rosario T Phys Imaging Radiat Oncol. 2022; 23:92-96.

PMID: 35844255 PMC: 9283928. DOI: 10.1016/j.phro.2022.06.013.


Proximal seminal vesicle displacement and margins for prostate cancer radiotherapy.

Joon D, Chao M, Piccolo A, Schneider M, Anderson N, Handley M J Med Radiat Sci. 2021; 68(3):289-297.

PMID: 33432719 PMC: 8424309. DOI: 10.1002/jmrs.457.