Do Different Turbid Media with Matched Bulk Optical Properties Also Exhibit Similar Polarization Properties?

Overview
Specialty Radiology
Date 2011 Dec 14
PMID 22162815
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

We here investigate polarimetric behavior of thick samples of porcine liver, Intralipid, and microsphere-based tissue phantoms whose absorption and scattering properties are matched. Using polarized light we measured reflection mode Mueller matrices and derived linear/circular/total depolarization rates, based on polar decomposition. According to our results, phantoms exhibit greater depolarization rates in the backscattering geometry than the liver sample. The enhanced tissue polarization preservation differs from previous reports of polarimetric transmission studies, with the likely cause of this difference being the angular dependence of the single-scattering phase function. Also, Intralipid approximated polarimetric liver behavior well, whereas the polystyrene phantoms did not.

Citing Articles

Mueller matrix analysis of a biologically sourced engineered tissue construct as polarimetric phantom.

Lin Z, Madnick S, Burrow J, Morgan J, Toussaint Jr K J Biomed Opt. 2024; 29(10):106002.

PMID: 39474362 PMC: 11521148. DOI: 10.1117/1.JBO.29.10.106002.


Polarization memory rate as a metric to differentiate benign and malignant tissues.

Louie D, Tchvialeva L, Kalia S, Lui H, Lee T Biomed Opt Express. 2022; 13(2):620-632.

PMID: 35284168 PMC: 8884210. DOI: 10.1364/BOE.446094.


Discriminating turbid media by scatterer size and scattering coefficient using backscattered linearly and circularly polarized light.

Singh M, Vitkin I Biomed Opt Express. 2021; 12(11):6831-6843.

PMID: 34858683 PMC: 8606157. DOI: 10.1364/BOE.438631.


Controlling the optical pathlength in continuous-wave reflectance spectroscopy using polarization.

Macdonald C, Sridhar S, Do H, Luna-Labrador J, Adel M, Da Silva A Biomed Opt Express. 2021; 12(7):4401-4413.

PMID: 34457421 PMC: 8367255. DOI: 10.1364/BOE.426627.


Evaluating β-amyloidosis progression in Alzheimer's disease with Mueller polarimetry.

Borovkova M, Bykov A, Popov A, Pierangelo A, Novikova T, Pahnke J Biomed Opt Express. 2020; 11(8):4509-4519.

PMID: 32923060 PMC: 7449745. DOI: 10.1364/BOE.396294.


References
1.
Schmitt J, Gandjbakhche A, Bonner R . Use of polarized light to discriminate short-path photons in a multiply scattering medium. Appl Opt. 2010; 31(30):6535-46. DOI: 10.1364/AO.31.006535. View

2.
Kim A, Roy M, Dadani F, Wilson B . A fiberoptic reflectance probe with multiple source-collector separations to increase the dynamic range of derived tissue optical absorption and scattering coefficients. Opt Express. 2010; 18(6):5580-94. DOI: 10.1364/OE.18.005580. View

3.
Wood M, Guo X, Vitkin I . Polarized light propagation in multiply scattering media exhibiting both linear birefringence and optical activity: Monte Carlo model and experimental methodology. J Biomed Opt. 2007; 12(1):014029. DOI: 10.1117/1.2434980. View

4.
Manhas S, Swami M, Buddhiwant P, Ghosh N, Gupta P, Singh J . Mueller matrix approach for determination of optical rotation in chiral turbid media in backscattering geometry. Opt Express. 2009; 14(1):190-202. DOI: 10.1364/opex.14.000190. View

5.
Sankaran V, Everett M, Maitland D, Walsh Jr J . Comparison of polarized-light propagation in biological tissue and phantoms. Opt Lett. 2007; 24(15):1044-6. DOI: 10.1364/ol.24.001044. View