Validation of the Oral Health Impact Profile (OHIP-20sp) for Spanish Edentulous Patients
Overview
Affiliations
Objectives: The purposes of this study are to validate the indicator of Oral Health Impact Profile for edentulous patients (OHIP-20sp) in the Spanish population and to analyze the factorial construct of the prosthetic well-being.
Study Design: [corrected] A total of twenty-one (n=21) edentulous patients wearing mandibular implant-overdentures on Locator® (LO) and twenty (n=20) with complete dentures (CD) were retrospectively evaluated in this study. All participants were recruited consecutively and were treated in the previous academic year 2009-2010 by professors of the University of Salamanca. Reliability analyses and validity tests were performed in order to evaluate the psychometric properties of OHIP-20sp employing two different total score methods (additional and simple count). A retrospective evaluation of the impact of the prosthetic treatment was captured with an evaluative instrument derived from OHIP-20, and named POST-OHIP-13.
Results: The reliability coefficient (Cronbach's alpha = 0.91) has shown a high internal consistency. Item-total correlations coefficients ranged from 0.46 and 0.81. Five factors, named as disability, functional comfort, psychosocial impact, pain-discomfort and functional limitations were identified as principal components of the construct, explaining almost 85% of the variance. The 48% of the sample felt at least one impact in an occasional or more frequently manner (generally food packing). The global transition judgment of the prosthetic treatment using the POST-OHIP-13 was significantly higher in group LO than in the CD group.
Conclusions: OHIP-20 seems to be a reliable and valid indicator to measure oral impact and satisfaction in the Spanish edentulous population. The underlying construct is comprised by 5 factors named as disability, functional comfort, psychosocial impact, pain-discomfort and functional limitations.
Fouda S, Gad M, Ellakany P, Zayat M, AlGhamdi M, Abdelrahman H Saudi Dent J. 2024; 36(7):1000-1005.
PMID: 39035561 PMC: 11255941. DOI: 10.1016/j.sdentj.2024.04.006.
Psychometric properties of ohip-edent b&h for conventional complete denture wearers.
Postic S PLoS One. 2023; 18(1):e0280012.
PMID: 36662729 PMC: 9858044. DOI: 10.1371/journal.pone.0280012.
Montero J, Guadilla Y, Flores J, Pardal-Pelaez B, Quispe-Lopez N, Gomez-Polo C J Clin Med. 2021; 10(19).
PMID: 34640607 PMC: 8509672. DOI: 10.3390/jcm10194589.
Montero J, Dib A, Guadilla Y, Flores J, Pardal-Pelaez B, Quispe-Lopez N J Clin Med. 2021; 10(16).
PMID: 34441773 PMC: 8396916. DOI: 10.3390/jcm10163477.
Bural C, Geckili O, Erdogan O, Bektas-Kayhan K, Dayan S Eur Oral Res. 2021; 55(2):67-73.
PMID: 34250472 PMC: 8244939. DOI: 10.26650/eor.20210007.