Higher Complication Risk of Totally Implantable Venous Access Port Systems in Patients with Advanced Cancer - a Single Institution Retrospective Analysis
Overview
Authors
Affiliations
Background: Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer.
Aim: The aim of this study was to assess the risk of port system failure in patients with advanced cancer.
Design: We conducted a retrospective cohort study in a comprehensive cancer centre.
Setting/participants: A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion.
Results: Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion.
Conclusions: Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.
Jia J, Fan X, Zhang W, Xu Z, Wu M, Zhan Y Oncol Lett. 2024; 28(1):326.
PMID: 38807672 PMC: 11130750. DOI: 10.3892/ol.2024.14459.
Wong C, Choi H, Lee V Cancers (Basel). 2023; 15(19).
PMID: 37835406 PMC: 10571956. DOI: 10.3390/cancers15194712.
Outcomes following port-a-catheter placement in the Medicare population.
Khalid S, Maasarani S, Shanker R, Wiegmann A, Wu R, Skertich N Surg Open Sci. 2021; 3:39-43.
PMID: 33937739 PMC: 8077681. DOI: 10.1016/j.sopen.2020.10.002.
Role of Lock Therapy for Long-Term Catheter-Related Infections by Multidrug-Resistant Bacteria.
Freire M, Pierrotti L, Zerati A, Benites L, da Motta-Leal Filho J, Ibrahim K Antimicrob Agents Chemother. 2018; 62(9).
PMID: 29987150 PMC: 6125525. DOI: 10.1128/AAC.00569-18.
A Study of Use of "PORT" Catheter in Patients with Cancer: A Single-Center Experience.
Madabhavi I, Patel A, Sarkar M, Anand A, Panchal H, Parikh S Clin Med Insights Oncol. 2017; 11:1179554917691031.
PMID: 28469510 PMC: 5395272. DOI: 10.1177/1179554917691031.