» Articles » PMID: 22101758

Continuous and Noninvasive Measurement of Systolic and Diastolic Blood Pressure by One Mathematical Model with the Same Model Parameters and Two Separate Pulse Wave Velocities

Overview
Journal Ann Biomed Eng
Date 2011 Nov 22
PMID 22101758
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

There is keen interest in continuous and noninvasive blood pressure (BP) measurement. However, many technologies have a shortcoming of complex mechanical structure. In our study, two arterial pulses are acquired by photoplethysmography (PPG) at ear and toe in order to explore a new method of measuring BP by pulse wave velocity (PWV). We previously validated and reported a BP-PWV mathematical model with measurements from humans with no evidence of cardiovascular disease, but were only able to determine PWV related to diastolic blood pressure (DBP). In this paper, we propose methods of identifying pulse transmit time (PTT) in low, normal and high systolic blood pressure (SBP) conditions. By averaging the PTT's of incident wave and reflected wave for non-systematic error reduction, we obtain a PWV that is suitable for estimating SBP. SBP and DBP are estimated by two separate PWV's based on the previously calibrated models. Experimental measurements are conducted on 26 subjects (age 19 ± 1 and 60 ± 1) with no evidence of cardiovascular disease. The measurement errors (Mean Deviation = 2.16 mmHg (SBP) and 1.49 mmHg (DBP); Standard Deviation = 6.23 mmHg (SBP) and 6.51 mmHg (DBP)) satisfy the accuracy criteria of Association for the Advancement of Medical Instrumentation. The results verify that SBP and DBP can be estimated by one mathematical model with the same model parameters and two separate PWV's.

Citing Articles

Importance of Considering Temporal Variations in Pulse Wave Velocity for Accurate Blood Pressure Prediction.

Bantwal A, Bhayadia A, Meng H Ann Biomed Eng. 2025; .

PMID: 39912848 DOI: 10.1007/s10439-025-03681-7.


Video-based estimation of blood pressure.

Dasari A, Jeni L, Tucker C PLoS One. 2025; 20(1):e0311654.

PMID: 39883614 PMC: 11781723. DOI: 10.1371/journal.pone.0311654.


Effect of Nonlinear Hyperelastic Property of Arterial Tissues on the Pulse Wave Velocity Based on the Unified-Fiber-Distribution (UFD) Model.

Dong H, Liu M, Woodall J, Leshnower B, Gleason Jr R Ann Biomed Eng. 2023; 51(11):2441-2452.

PMID: 37326947 DOI: 10.1007/s10439-023-03275-1.


Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review.

Zhou Z, Cui T, Li D, Jian J, Li Z, Ji S Materials (Basel). 2023; 16(6).

PMID: 36984013 PMC: 10057755. DOI: 10.3390/ma16062133.


Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges.

Khan Mamun M, Sherif A Bioengineering (Basel). 2023; 10(1).