» Articles » PMID: 22069079

Quantification of Kinase Activity in Cell Lysates Via Photopatterned Macroporous Poly(ethylene Glycol) Hydrogel Arrays in Microfluidic Channels

Overview
Date 2011 Nov 10
PMID 22069079
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

The efficacy of tyrosine kinase inhibitors (TKIs) as cancer therapeutics varies amongst individual patients as a result of patient-specific differences in molecular regulation of cancer development and progression, and acquisition of resistance to TKIs during therapy. A sensitive assay that can quantify kinase activity and predict inhibition of that activity from minimally invasive patient tissue samples may aid design of efficacious individualized TKI treatments. A microfluidic format can be useful in reducing limitations in standard protein kinase assays, including sensitivity required and low sample volume available. We present photopatterned macroporous poly(ethylene glycol) diacrylate hydrogel pillars functionalized with kinase substrates within microchannels for quantifying kinase activity in complex cellular lysates. We determined the effect of using a porogen to induce macroporosity in hydrogel pillars and showed that hydrogel poration enhanced the sensitivity of detecting Bcr-Abl activity in cell lysates by an order of magnitude. Bcr-Abl tyrosine kinase activity in K562 cell lysates could be detected from 0.01 μg/μL of cell lysate, corresponding to approximately 500 cells, using GST-Crkl immobilized in macroporous hydrogels. This device was also capable of quantifying inhibition of Bcr-Abl activity by imatinib mesylate, which demonstrates the potential to predict the biochemical response to drug inhibitors. These results indicate that microfluidic devices containing macroporous hydrogels functionalized with kinase substrates provide a promising platform for sensitive and specific quantification of kinase activity and efficacy of kinase inhibitors in cancer cell lysates.

Citing Articles

Convection-driven microfabricated hydrogels for rapid biosensing.

Cheng C, Harpster M, Oakey J Analyst. 2020; 145(18):5981-5988.

PMID: 32820752 PMC: 7819640. DOI: 10.1039/d0an01069c.


Fabrication of Functional Biomaterial Microstructures by in Situ Photopolymerization and Photodegradation.

LeValley P, Noren B, Kharkar P, Kloxin A, Gatlin J, Oakey J ACS Biomater Sci Eng. 2020; 4(8):3078-3087.

PMID: 31984222 PMC: 6980224. DOI: 10.1021/acsbiomaterials.8b00350.


Hydrogel microparticles for biosensing.

Le Goff G, Srinivas R, Hill W, Doyle P Eur Polym J. 2015; 72:386-412.

PMID: 26594056 PMC: 4648376. DOI: 10.1016/j.eurpolymj.2015.02.022.


A lateral electrophoretic flow diagnostic assay.

Lin R, Skandarajah A, Gerver R, Neira H, Fletcher D, Herr A Lab Chip. 2015; 15(6):1488-96.

PMID: 25608872 PMC: 4383188. DOI: 10.1039/c4lc01370k.


Protein analytical assays for diagnosing, monitoring, and choosing treatment for cancer patients.

Powers A, Palecek S J Healthc Eng. 2014; 3(4):503-534.

PMID: 25147725 PMC: 4137876. DOI: 10.1260/2040-2295.3.4.503.


References
1.
Corbin A, La Rosee P, Stoffregen E, Druker B, Deininger M . Several Bcr-Abl kinase domain mutants associated with imatinib mesylate resistance remain sensitive to imatinib. Blood. 2003; 101(11):4611-4. DOI: 10.1182/blood-2002-12-3659. View

2.
Ross , Fletcher . The HER-2/neu Oncogene in Breast Cancer: Prognostic Factor, Predictive Factor, and Target for Therapy. Oncologist. 1999; 3(4):237-252. View

3.
Armstrong J, Wenby R, Meiselman H, Fisher T . The hydrodynamic radii of macromolecules and their effect on red blood cell aggregation. Biophys J. 2004; 87(6):4259-70. PMC: 1304934. DOI: 10.1529/biophysj.104.047746. View

4.
Fang C, Wang Y, Vu N, Lin W, Hsieh Y, Rubbi L . Integrated microfluidic and imaging platform for a kinase activity radioassay to analyze minute patient cancer samples. Cancer Res. 2010; 70(21):8299-308. PMC: 3989903. DOI: 10.1158/0008-5472.CAN-10-0851. View

5.
Trigiante , Gast , Robertson . Pseudo First-Order Cleavage of an Immobilized Substrate by an Enzyme Undergoing Two-Dimensional Surface Diffusion. J Colloid Interface Sci. 1999; 213(1):81-86. DOI: 10.1006/jcis.1999.6109. View