» Articles » PMID: 22051495

Accuracy and Reliability of Buccal Bone Height and Thickness Measurements from Cone-beam Computed Tomography Imaging

Overview
Publisher Elsevier
Specialty Dentistry
Date 2011 Nov 5
PMID 22051495
Citations 82
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Cone-beam computed tomography (CBCT) imaging has broadened opportunities for examining morphologic aspects of the craniofacial complex, including alveolar bone, but limitations of the technology have yet to be defined. Through the use of comparisons with direct measurements, the purpose of this study was to investigate the accuracy and reliability of buccal alveolar bone height and thickness measurements derived from CBCT images.

Methods: Twelve embalmed cadaver heads (5 female, 7 male; mean age: 77 years) were scanned with an i-CAT 17-19 unit (Imaging Sciences International, Hatfield, Pa) at 0.3 mm voxel size. Buccal alveolar bone height and thickness measurements of 65 teeth were made in standardized radiographic slices and compared with direct measurements made by dissection. All measurements were repeated 3 times by 2 independent raters and examined for intrarater and interrater reliability. Measurement means were compared with 2-tailed t tests. Agreement between direct and CBCT measurements was assessed by concordance correlation coefficients, Pearson correlation coefficients, and Bland-Altman plots.

Results: Intrarater reliability was high as were interrater correlations for all measurements (≥0.97) except CBCT buccal bone thickness (0.90). CBCT measurements did not differ significantly from direct measurements, and there was no pattern of underestimation or overestimation. The mean absolute differences were 0.30 mm in buccal bone height and 0.13 mm in buccal bone thickness with 95% limits of agreement of -0.77 to 0.81 mm, and -0.32 to 0.38 mm, respectively. Agreement between the 2 methods was higher for the measurements of buccal bone height than buccal bone thickness, as demonstrated by concordance correlation coefficients of 0.98 and 0.86, respectively.

Conclusions: For the protocol used in this study, CBCT can be used to quantitatively assess buccal bone height and buccal bone thickness with high precision and accuracy. Comparing the 2 sets of CBCT measurements, buccal bone height had greater reliability and agreement with direct measurements than did the buccal bone thickness measurements.

Citing Articles

Validation of novel measurement protocols proposed for the standardized assessment of crestal bone levels: A cone-beam computed tomography study.

Fahd A, Hussien A, Ellabban M, Shatat Z Imaging Sci Dent. 2025; 54(4):354-361.

PMID: 39744555 PMC: 11685304. DOI: 10.5624/isd.20240073.


Effects of the passive self-ligating system on alveolar bone thickness, dental inclinations, and arch dimensions.

Matias M, Vieira B, Freitas K, Pinzan-Vercelino C, Cotrin P, Valarelli F J Clin Exp Dent. 2024; 16(11):e1361-e1370.

PMID: 39670041 PMC: 11632730. DOI: 10.4317/jced.61845.


Evaluation of the Impact of Smoking on Orthodontic Treatment.

S S, Mohan R, Chandrasekaran D, Purushothaman D, Tandon A, Angrish N Cureus. 2024; 16(11):e73431.

PMID: 39664131 PMC: 11633074. DOI: 10.7759/cureus.73431.


Tomographic diagnosis of alveolar bone coverage impact in orthodontic planning: cross-sectional study.

Montanha-Andrade K, Ferreira P, de Sena A, Cury P, Crusoe-Rebello I Dental Press J Orthod. 2024; 29(5):e242446.

PMID: 39383372 PMC: 11457962. DOI: 10.1590/2177-6709.29.5.e242446.oar.


Accuracy of intraoral ultrasound to evaluate alveolar bone level: an ex vivo study in human cadavers.

Corbea C, Le L, Kaipatur N, Li M, Nguyen K, Heo G Oral Radiol. 2024; 41(1):33-40.

PMID: 39251497 DOI: 10.1007/s11282-024-00773-3.