Evaluation of the Kinect™ Sensor for 3-D Kinematic Measurement in the Workplace

Overview
Journal Appl Ergon
Specialty Psychology
Date 2011 Oct 25
PMID 22018839
Citations 47
Authors
Affiliations
Soon will be listed here.
Abstract

Recording posture and movement is important for determining risk of musculoskeletal injury in the workplace, but existing motion capture systems are not suited for field work. Estimates of the 3-D relative positions of four 0.10 m cubes from the Kinect were compared to estimates from a Vicon motion capture system to determine whether the hardware sensing components were sensitive enough to be used as a portable 3-D motion capture system for workplace ergonomic assessments. The root-mean-squared errors (SD) were 0.0065 m (0.0048 m), 0.0109 m (0.0059 m), 0.0057 m (0.0042 m) in the x, y and z directions (with x axis to the right, y axis away from the sensor and z axis upwards). These data were collected over a range of 1.0-3.0m from the device covering a field of view of 54.0 degrees horizontally and 39.1 degrees vertically. Requirements for software, hardware and subject preparation were also considered to determine the usability of the Kinect in the field.

Citing Articles

Feasibility of using low-cost markerless motion capture for assessing functional outcomes after lower extremity musculoskeletal cancer surgery.

Furtado S, Galna B, Godfrey A, Rochester L, Gerrand C PLoS One. 2024; 19(3):e0300351.

PMID: 38547229 PMC: 10977781. DOI: 10.1371/journal.pone.0300351.


Fast Multichannel Inverse Design through Augmented Partial Factorization.

Li S, Lin H, Hsu C ACS Photonics. 2024; 11(2):378-384.

PMID: 38405390 PMC: 10885196. DOI: 10.1021/acsphotonics.3c00911.


Investigation of the Kinematic Upper-Limb Movement Assessment (KUMA): A Pilot Study.

Eftekhar P, Li M, Semple M, Richardson D, Brooks D, Mochizuki G Physiother Can. 2023; 74(3):316-323.

PMID: 37325208 PMC: 10262831. DOI: 10.3138/ptc-2019-0023.


Accuracy and Correlation of the Kinect-Based Semi-Automatic Scoring Method for Measuring Anomalous Head Posture as Compared to the CROM Device.

Yamamoto M, Yagasaki T, Ichikawa S, Nakamura T, Konishi Y, Yokoyama Y Clin Ophthalmol. 2022; 16:4033-4040.

PMID: 36523850 PMC: 9744893. DOI: 10.2147/OPTH.S381874.


The Automatization of the Gait Analysis by the Vicon Video System: A Pilot Study.

Smirnova V, Khamatnurova R, Kharin N, Yaikova E, Baltina T, Sachenkov O Sensors (Basel). 2022; 22(19).

PMID: 36236276 PMC: 9571292. DOI: 10.3390/s22197178.