» Articles » PMID: 22012542

Influence of Relative Humidity on Prolonged Exercise Capacity in a Warm Environment

Overview
Specialty Physiology
Date 2011 Oct 21
PMID 22012542
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

This study examined the influence of relative humidity on endurance exercise performance in a warm environment. Eight male volunteers performed four cycle exercise trials at 70% maximum oxygen uptake until volitional exhaustion in an environmental chamber maintained at 30.2 ± 0.2°C. Volunteers were tested under four relative humidity (rh) conditions: 24, 40, 60 and 80%. Core and weighted mean skin temperature, heart rate, skin blood flow, and cutaneous vascular conductance were recorded at rest and at regular intervals during exercise. Mean ± SD time to exhaustion was 68 ± 19, 60 ± 17, 54 ± 17, and 46 ± 14 min at 24, 40, 60, and 80% rh, respectively (P < 0.001); exercise time was significantly less at 60% (P = 0.013) and 80% (P = 0.005) rh than recorded at 24% rh. There were no differences in core temperature (P = 0.480) and heart rate (P = 0.097) between trials. Core temperature at exhaustion was 39.0 ± 0.3°C at 24, 40, and 60% rh and 39.1 ± 0.3°C at 80% rh (P = 0.159). Mean skin temperature at the point of exhaustion was higher at 80% rh than at 24% rh (P < 0.001). Total sweat loss was similar between trials (P = 0.345), but sweating rate was higher at 60 and 80% rh than at 24% rh (P < 0.001). The results suggest that exercise capacity at moderate intensity in a warm environment is progressively impaired as the relative humidity increases.

Citing Articles

The influence of meteorological factors on the technical performance of football teams during matches.

Zhong Y, Zhang S, Yi Q, Gomez Ruano M Biol Sport. 2024; 41(4):165-172.

PMID: 39416501 PMC: 11474995. DOI: 10.5114/biolsport.2024.136091.


Associations between environmental factors and running performance: An observational study of the Berlin Marathon.

Weiss K, Valero D, Villiger E, Scheer V, Thuany M, Aidar F PLoS One. 2024; 19(10):e0312097.

PMID: 39413062 PMC: 11482731. DOI: 10.1371/journal.pone.0312097.


Pre-, Per- and post-cooling strategies used by competitive tennis players in hot dry and hot humid conditions.

Robin N, Crespo M, Ishihara T, Carien R, Brechbuhl C, Hue O Front Sports Act Living. 2024; 6:1427066.

PMID: 39359487 PMC: 11445033. DOI: 10.3389/fspor.2024.1427066.


Different humidity environments do not affect the subsequent exercise ability of college football players after aerobic high-intensity interval training.

Fan Y, Zhang B, Wang Y, Wu H Sci Rep. 2024; 14(1):16205.

PMID: 39003355 PMC: 11246416. DOI: 10.1038/s41598-024-66757-9.


Effect of a cajuína hydroelectrolytic drink on the physical performance and hydration status of recreational runners.

Silvino V, Batista M, Neto M, Ribeiro A, Nascimento P, Barros E Curr Res Physiol. 2024; 7:100119.

PMID: 38357495 PMC: 10864873. DOI: 10.1016/j.crphys.2024.100119.


References
1.
Pitsiladis Y, Maughan R . The effects of exercise and diet manipulation on the capacity to perform prolonged exercise in the heat and in the cold in trained humans. J Physiol. 1999; 517 ( Pt 3):919-30. PMC: 2269386. DOI: 10.1111/j.1469-7793.1999.0919s.x. View

2.
PARKIN J, Carey M, Zhao S, Febbraio M . Effect of ambient temperature on human skeletal muscle metabolism during fatiguing submaximal exercise. J Appl Physiol (1985). 1999; 86(3):902-8. DOI: 10.1152/jappl.1999.86.3.902. View

3.
Fuller A, Carter R, Mitchell D . Brain and abdominal temperatures at fatigue in rats exercising in the heat. J Appl Physiol (1985). 1998; 84(3):877-83. DOI: 10.1152/jappl.1998.84.3.877. View

4.
Galloway S, Maughan R . The effects of substrate and fluid provision on thermoregulatory and metabolic responses to prolonged exercise in a hot environment. J Sports Sci. 2000; 18(5):339-51. DOI: 10.1080/026404100402403. View

5.
Cabanac M, Massonnet B, Belaiche R . Preferred skin temperature as a function of internal and mean skin temperature. J Appl Physiol. 1972; 33(6):699-703. DOI: 10.1152/jappl.1972.33.6.699. View