Distance Measurement in Middle Ear Surgery Using a Telemanipulator

Overview
Publisher Springer
Date 2011 Oct 19
PMID 22003598
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

In this article, a new tool for the intraoperative measurement of distances within the middle ear by means of a micromanipulator is presented. The purpose of this work was to offer the surgeon a highly accurate tool for measuring the distances between two points in the 3D operational field. The tool can be useful in various operations; this article focuses, however, on measuring the distance between the stapes footplate and the long process of the incus of the middle ear. This distance is important for estimating the proper prosthesis length in stapedotomy for treating otosclerosis. We evaluated the system using a simplified mechanical model. Our results show that the system can measure distances with a maximum error of 0.04 mm.

Citing Articles

Commentary to: Predictable prosthesis length on a high-resolution CT scan before a stapedotomy.

Dasli S, Selcuk A Eur Arch Otorhinolaryngol. 2018; 275(12):3103-3104.

PMID: 30255203 DOI: 10.1007/s00405-018-5143-9.


The distance between stapedial footplate and incus in otosclerosis surgery.

Eftekharian A, Roozbahany N, Shomali S J Otol. 2018; 10(1):18-20.

PMID: 29937777 PMC: 6002554. DOI: 10.1016/j.joto.2015.07.002.


Obliquity of the Stapes in Otosclerosis: A New Radiological Sign.

Anand V, Udayabhanu H, Subramaniam B Int Arch Otorhinolaryngol. 2016; 20(2):94-8.

PMID: 27096011 PMC: 4835337. DOI: 10.1055/s-0036-1579743.


[Clinical use of a micromanipulator system: preliminary clinical experience in middle ear surgery].

Strauss G, Maier T, Krinninger M, Berger T, Dietz A, Luth T HNO. 2012; 60(9):807-13.

PMID: 22767192 DOI: 10.1007/s00106-012-2540-z.

References
1.
Bozzato A, Struffert T, Hertel V, Iro H, Hornung J . Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses. Eur Radiol. 2009; 20(3):566-71. DOI: 10.1007/s00330-009-1582-4. View

2.
Tokuda J, Fischer G, Papademetris X, Yaniv Z, Ibanez L, Cheng P . OpenIGTLink: an open network protocol for image-guided therapy environment. Int J Med Robot. 2009; 5(4):423-34. PMC: 2811069. DOI: 10.1002/rcs.274. View

3.
Strauss G, Hipp S, Fischer M, Hofer M, Munz F, Dietz A . [Intraoperative volumetry in ENT surgery. Objectivation of surgical success by the volume control system]. HNO. 2010; 58(8):839-45. DOI: 10.1007/s00106-010-2128-4. View

4.
Gros A, Vatovec J, Zargi M, Jenko K . Success rate in revision stapes surgery for otosclerosis. Otol Neurotol. 2005; 26(6):1143-8. DOI: 10.1097/01.mao.0000172414.64907.9d. View

5.
Heermann R, Hauger C, Issing P, Lenarz T . [Application of Optical Coherence Tomography (OCT) in middle ear surgery]. Laryngorhinootologie. 2002; 81(6):400-5. DOI: 10.1055/s-2002-32213. View