Comparison of Laparoendoscopic Single-site Donor Nephrectomy and Conventional Laparoscopic Donor Nephrectomy: Donor and Recipient Outcomes

Overview
Journal Urology
Specialty Urology
Date 2011 Oct 15
PMID 21996107
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To present a comparison of perioperative donor outcomes and recipient graft function in a series of patients undergoing laparoendoscopic single-site donor nephrectomy (LESS-DN) versus conventional laparoscopic donor nephrectomy (LDN).

Methods: Data were collected for 50 consecutive LESS-DN patients and a matched cohort of 50 LDN patients. The donor outcomes analyzed included operative time, estimated blood loss, complications, visual analog pain scores, and recovery time. The recipient outcomes analyzed included serum creatinine at discharge and follow-up and the incidence of delayed graft function.

Results: The mean total operative time was shorter in the LDN group than in the LESS-DN group (P < .0001). Linear regression analysis of the LESS-DN operative times relative to case number showed a significant decrease in the operative time with increasing case number (r(2) = 0.19, P = .002). No statistically significant differences were found in estimated blood loss, warm ischemia time, length of stay, or visual analog pain scores between the 2 groups. However, the surgical incision was significantly smaller in the LESS-DN group (P < .0001). After discharge, the patient-reported time to complete recovery was faster in the LESS-DN group (P = .01). The incidence of complications was similar in both groups; however, major complications only occurred in the LDN group. No differences were found in the recipient serum creatinine values or the incidence of delayed graft function.

Conclusion: Our initial experience with LESS-DN is encouraging. This retrospective matched-pair comparison between LESS-DN and LDN suggests that the single-port approach might be associated with quicker convalescence. Longer operative times in the LESS-DN group could simply represent the learning curve of a novel procedure.

Citing Articles

Single-incision laparoscopic totally extraperitoneal retrieval of retroperitoneal vas deferens in vasovasostomy for obstructive azoospermia patients postchildhood bilateral herniorrhaphy.

Zhang C, Wu W, Xu J, Zhao J, Zhi E, Huang Y Asian J Androl. 2024; 27(1):137-138.

PMID: 39119662 PMC: 11784948. DOI: 10.4103/aja202456.


Robotic Single-Port Donor Nephrectomy with the da Vinci SP® Surgical System.

Garden E, Al-Alao O, Razdan S, Mullen G, Florman S, Palese M JSLS. 2021; 25(4).

PMID: 34949909 PMC: 8692076. DOI: 10.4293/JSLS.2021.00062.


Minimally invasive donor nephrectomy: current state of the art.

Shockcor N, Sultan S, Alvarez-Casas J, Brazio P, Phelan M, LaMattina J Langenbecks Arch Surg. 2018; 403(6):681-691.

PMID: 30132134 DOI: 10.1007/s00423-018-1700-3.


First Canadian experience with robotic laparoendoscopic single-site vs. standard laparoscopic living-donor nephrectomy: A prospective comparative study.

Luke P, Aquil S, Alharbi B, Sharma H, Sener A Can Urol Assoc J. 2018; 12(11):E440-E446.

PMID: 29989887 PMC: 6217949. DOI: 10.5489/cuaj.5275.


Laparoendoscopic single-site donor nephrectomy (LESS-DN) versus standard laparoscopic donor nephrectomy.

Gupta A, Ahmed K, Kynaston H, Dasgupta P, Chlosta P, Aboumarzouk O Cochrane Database Syst Rev. 2016; (5):CD010850.

PMID: 27230690 PMC: 6823261. DOI: 10.1002/14651858.CD010850.pub2.