Objective: The study objective was to compare endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) with mediastinoscopy for mediastinal lymph node staging of potentially resectable non-small cell lung cancer.

Methods: Patients with confirmed or suspected non-small cell lung cancer who required mediastinoscopy to determine suitability for lung cancer resection were entered into the trial. All patients underwent EBUS-TBNA followed by mediastinoscopy under general anesthesia. If both were negative for N2 or N3 disease, the patient underwent pulmonary resection and mediastinal lymphadenectomy.

Results: Between July 2006 and August 2010, 190 patients were registered in the study, 159 enrolled, and 153 were eligible for analysis. EBUS-TBNA and mediastinoscopy sampled an average of 3 and 4 lymph node stations per patient, respectively. The mean short axis of the lymph node biopsied by EBUS-TBNA was 6.9 ± 2.9 mm. The prevalence of N2/N3 disease was 35% (53/153). There was excellent agreement between EBUS-TBNA and mediastinoscopy for mediastinal staging in 136 patients (91%; Kappa, 0.8; 95% confidence interval, 0.7-0.9). Specificity and positive predictive value for both techniques were 100%. The sensitivity, negative predictive value, and diagnostic accuracy for mediastinal lymph node staging for EBUS-TBNA and mediastinoscopy were 81%, 91%, 93%, and 79%, 90%, 93%, respectively. No significant differences were found between EBUS-TBNA and mediastinoscopy in determining the true pathologic N stage (McNemar's test, P = .78). There were no complications from EBUS-TBNA. Minor complications from mediastinoscopy were observed in 4 patients (2.6%).

Conclusions: EBUS-TBNA and mediastinoscopy achieve similar results for the mediastinal staging of lung cancer. As performed in this study, EBUS-TBNA can replace mediastinoscopy in patients with potentially resectable non-small cell lung cancer.

Citing Articles

Diagnostic modalities in the mediastinum and the role of bronchoscopy in mediastinal assessment: a narrative review.

Dollin Y, Munoz Pineda J, Sung L, Hasteh F, Fortich M, Lopez A Mediastinum. 2025; 8():51.

PMID: 39781205 PMC: 11707438. DOI: 10.21037/med-24-32.


Deep learning-based prediction of nodal metastasis in lung cancer using endobronchial ultrasound.

Ishiwata T, Inage T, Aragaki M, Gregor A, Chen Z, Bernards N JTCVS Tech. 2024; 28:151-161.

PMID: 39669341 PMC: 11632323. DOI: 10.1016/j.xjtc.2024.09.008.


Feasibility of Endobronchial Ultrasound Guided Miniforceps Biopsy for PD-L1 Expression and Quantitative Tissue Analysis.

Wayne M, Moulton N, Weimholt C, Chenna P, Chen A Thorac Cancer. 2024; 16(2):e15502.

PMID: 39653689 PMC: 11735461. DOI: 10.1111/1759-7714.15502.


Utility of adding oesophageal to endobronchial endosonography when staging lung cancer: a randomised trial.

Oki M, Saka H, Seki Y, Kogure Y, Niwa H, Yamada A ERJ Open Res. 2024; 10(6).

PMID: 39624385 PMC: 11609961. DOI: 10.1183/23120541.00326-2024.


EBUS-TBNA in mediastinal staging of non-small cell lung cancer: comparison with pathological staging.

Braga S, Costa R, Magalhaes A, Fernandes G J Bras Pneumol. 2024; 50(3):e20230353.

PMID: 39166587 PMC: 11449611. DOI: 10.36416/1806-3756/e20230353.