» Articles » PMID: 21958903

Validity and Ease of Use of a Computerized Hess Chart

Overview
Journal J AAPOS
Specialty Pediatrics
Date 2011 Oct 1
PMID 21958903
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate agreement between computerized and conventional methods for obtaining Hess charts and to compare relative ease of use of both methods.

Methods: Hess charts of 65 patients were obtained by the use of the computerized Assaf Ocular Motility Analyzer (OMA) and the conventional Lees screen method. The Hess charts produced by each method were compared with a previously described scoring system. Patients compared the ease of testing by using a 5-point Likert scale.

Results: For horizontal deviations of the right eye, the OMA provided a significantly larger (P = 0.0001) deviation (301° ± 267°) than the Lees screen (204° ± 306°). The Lees screen gave a significantly larger score for vertical deviations of the left eye (117° ± 158° vs 96° ± 129°; P = 0.003). Vertical deviations of the right eye and horizontal deviations of the left eye did not differ significantly between tests. Patients required the same amount of time to complete both tests, but the OMA was slightly easier to perform than the Lees screen (Likert score, 1.2 ± 0.5 vs 1.3 ± 0.4; P = 0.046).

Conclusions: The scores measured were larger with OMA in the horizontal and smaller in the vertical direction than with the Lees screen in some directions. Although the OMA did not save time, patients found it easier to perform than the Lees screen. The OMA may be considered a useful alternative to the Lees screen.

Citing Articles

Hess Lancaster Screen Test with Eye Tracker: An Objective Method for the Measurement of Binocular Gaze Direction.

Orduna-Hospital E, Maurain-Orera L, Lopez-de-la-Fuente C, Sanchez-Cano A Life (Basel). 2023; 13(3).

PMID: 36983824 PMC: 10054291. DOI: 10.3390/life13030668.


Preliminary data on a novel smart glasses system for measuring the angle of deviation in strabismus.

Lee L, Feng K, Chuang P, Chen Y, Chien K Eye (Lond). 2023; 37(13):2700-2706.

PMID: 36702909 PMC: 10483031. DOI: 10.1038/s41433-023-02402-5.


Peribulbar injection of glucocorticoids for thyroid-associated ophthalmopathy and factors affecting therapeutic effectiveness: A retrospective cohort study of 386 cases.

Wang Y, Du B, Yang M, Zhu Y, He W Exp Ther Med. 2020; 20(3):2031-2038.

PMID: 32782513 PMC: 7401219. DOI: 10.3892/etm.2020.8896.


Quantifying Eye Alignment in Orbital Fracture Patients: The Digital Hess Screen.

Akkina S, Shabbir A, Lahti A, Mudumbai R, Chambers C, Moe K Facial Plast Surg Aesthet Med. 2020; 22(6):427-432.

PMID: 32456473 PMC: 7703130. DOI: 10.1089/fpsam.2020.0080.


Stepping into the virtual unknown: feasibility study of a virtual reality-based test of ocular misalignment.

Nesaratnam N, Thomas P, Vivian A Eye (Lond). 2017; 31(10):1503-1506.

PMID: 28574497 PMC: 5639201. DOI: 10.1038/eye.2017.97.