» Articles » PMID: 21935126

Femtosecond Laser Fabricated All-optical Fiber Sensors with Ultrahigh Refractive Index Sensitivity: Modeling and Experiment

Overview
Journal Opt Express
Date 2011 Sep 22
PMID 21935126
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

All-optical fiber sensors based on ultracompact fiber inline Mach-Zehnder interferometer (MZI) are fabricated by side-ablating a U-shape microcavity in a single-mode optical fiber with the fiber core partially removed using femtosecond (fs) laser pulses, in which the two light paths are accordingly formed in the remaining D-type fiber core and the U-shape microcavity. Beam propagation method (BPM) analysis is utilized to illustrate the dependences of good transmission spectra on parameters including the ablation depth, ablation length and the refractive index of U-shape micocavity, which gives some guidelines to optimize parameters for fs laser micromachining and predicts RI (refractive index) sensitivities within given RI ranges. The modeling results of ultrahigh RI sensitivities for gases and solutions are -3243.75 ± 0.65nm/RIU (refractive index unit) and -10789.29 ± 18.91nm/RIU, respectively. In RI testing experiments, the sensor exhibits ultrahigh RI sensitivities of -3754.79 ± 44.24nm/RIU with refractive indices ranging from 1.0001143 to 1.0002187 by testing different mixture ratios of N2 and He gases, and -12162.01 ± 173.92nm/RIU with refractive indices ranging from 1.3330 to 1.33801 by testing different concentrations of sucrose solutions, which is essentially in agreement with the modeling results.

Citing Articles

Curved Fabry-Pérot Ultrasound Detectors: Optical and Mechanical Analysis.

Rossi B, Cutolo M, Giaquinto M, Cusano A, Breglio G Sensors (Basel). 2025; 25(4).

PMID: 40006244 PMC: 11859234. DOI: 10.3390/s25041014.


Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing.

Eftimov T, Janik M, Koba M, Smietana M, Mikulic P, Bock W Sensors (Basel). 2020; 20(13).

PMID: 32635648 PMC: 7374516. DOI: 10.3390/s20133772.


Ultrasensitive Gas Refractometer Using Capillary-Based Mach-Zehnder Interferometer.

Chen H, Hu X, He M, Ren P, Zhang C, Qu H Sensors (Basel). 2020; 20(4).

PMID: 32098108 PMC: 7070851. DOI: 10.3390/s20041191.


Fiber Reshaping-Based Refractive Index Sensor Interrogated through Both Intensity and Wavelength Detection.

Ji P, Jiang S, Lee S Sensors (Basel). 2019; 19(11).

PMID: 31151242 PMC: 6603556. DOI: 10.3390/s19112477.


Ultrasensitive Mach-Zehnder Interferometric Temperature Sensor Based on Liquid-Filled D-Shaped Fiber Cavity.

Zhang H, Gao S, Luo Y, Chen Z, Xiong S, Wan L Sensors (Basel). 2018; 18(4).

PMID: 29673220 PMC: 5948719. DOI: 10.3390/s18041239.