» Articles » PMID: 21892370

Micro Soft Tissues Visualization Based on X-ray Phase-contrast Imaging

Overview
Publisher Bentham Open
Date 2011 Sep 6
PMID 21892370
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The current imaging methods have a limited ability to visualize microstructures of biological soft tissues. Small lesions cannot be detected at the early stage of the disease. Phase contrast imaging (PCI) is a novel non-invasive imaging technique that can provide high contrast images of soft tissues by the use of X-ray phase shift. It is a new choice in terms of non-invasively revealing soft tissue details. In this study, the lung and hepatic fibrosis models of mice and rats were used to investigate the ability of PCI in microstructures observation of soft tissues. Our results demonstrated that different liver fibrosis stages could be distinguished non-invasively by PCI. The three-dimensional morphology of a segment of blood vessel was constructed. Noteworthy, the blood clot inside the vessel was visualized in three dimensions which provided a precise description of vessel stenosis. Furthermore, the whole lung airways including the alveoli were obtained. We had specifically highlighted its use in the visualization and assessment of the alveoli. To our knowledge, this was the first time for non-invasive alveoli imaging using PCI. This finding may offer a new perspective on the diagnosis of respiratory disease. All the results confirmed that PCI will be a valuable tool in biological soft tissues imaging.

Citing Articles

Cartilage Tissue Engineering Approaches Need to Assess Fibrocartilage When Hydrogel Constructs Are Mechanically Loaded.

Alizadeh Sardroud H, Wanlin T, Chen X, Eames B Front Bioeng Biotechnol. 2022; 9:787538.

PMID: 35096790 PMC: 8790514. DOI: 10.3389/fbioe.2021.787538.


Computed Tomography as a Characterization Tool for Engineered Scaffolds with Biomedical Applications.

Olaret E, Stancu I, Iovu H, Serafim A Materials (Basel). 2021; 14(22).

PMID: 34832165 PMC: 8619049. DOI: 10.3390/ma14226763.


Microdissection of Human Esophagogastric Junction Wall with Phase-contrast X-ray CT Imaging.

Zhang J, Zhou G, Tian D, Lin R, Peng G, Su M Sci Rep. 2015; 5:13831.

PMID: 26346099 PMC: 4561904. DOI: 10.1038/srep13831.


Phase-contrast X-ray CT imaging of esophagus and esophageal carcinoma.

Zhang J, Tian D, Lin R, Zhou G, Peng G, Su M Sci Rep. 2014; 4:5332.

PMID: 24939041 PMC: 4061548. DOI: 10.1038/srep05332.


Imaging challenges in biomaterials and tissue engineering.

Appel A, Anastasio M, Larson J, Brey E Biomaterials. 2013; 34(28):6615-30.

PMID: 23768903 PMC: 3799904. DOI: 10.1016/j.biomaterials.2013.05.033.

References
1.
Kitchen M, Lewis R, Yagi N, Uesugi K, Paganin D, Hooper S . Phase contrast X-ray imaging of mice and rabbit lungs: a comparative study. Br J Radiol. 2005; 78(935):1018-27. DOI: 10.1259/bjr/13024611. View

2.
Cutroneo P, Polimeni G, Curcuruto R, Calapai G, Caputi A . Adverse reactions to contrast media: an analysis from spontaneous reporting data. Pharmacol Res. 2007; 56(1):35-41. DOI: 10.1016/j.phrs.2007.03.003. View

3.
Hoffman P, Mauer A, Vokes E . Lung cancer. Lancet. 2000; 355(9202):479-85. DOI: 10.1016/S0140-6736(00)82038-3. View

4.
Dienstag J, Goldin R, Heathcote E, Hann H, Woessner M, Stephenson S . Histological outcome during long-term lamivudine therapy. Gastroenterology. 2003; 124(1):105-17. DOI: 10.1053/gast.2003.50013. View

5.
Parsons D, Morgan K, Donnelley M, Fouras A, Crosbie J, Williams I . High-resolution visualization of airspace structures in intact mice via synchrotron phase-contrast X-ray imaging (PCXI). J Anat. 2009; 213(2):217-27. PMC: 2526115. DOI: 10.1111/j.1469-7580.2008.00950.x. View