» Articles » PMID: 21879972

Assessment of Repeatability of a Wireless, Inertial Sensor-based Lameness Evaluation System for Horses

Overview
Journal Am J Vet Res
Date 2011 Sep 2
PMID 21879972
Citations 66
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To determine repeatability of a wireless, inertial sensor-based lameness evaluation system in horses.

Animals: 236 horses.

Procedures: Horses were from 2 to 29 years of age and of various breeds and lameness disposition. All horses were instrumented with a wireless, inertial sensor-based motion analysis system on the head (accelerometer), pelvis (midline croup region [accelerometer]), and right forelimb (gyroscope) before evaluation in 2 consecutive trials, approximately 5 minutes apart, as the horse was trotted in a straight line. Signal-processing algorithms generated overall trial asymmetry measures for vertical head and pelvic movement and stride-by-stride differences in head and pelvic maximum and minimum positions between right and left sides of each stride. Repeatability was determined, and trial difference was determined for groups of horses with various numbers of strides for which data were collected per trial.

Results: Inertial sensor-based measures of torso movement asymmetry were repeatable. Repeatability for measures of torso asymmetry for determination of hind limb lameness was slightly greater than that for forelimb lameness. Collecting large numbers of strides degraded stride-to-stride repeatability but did not degrade intertrial repeatability.

Conclusions And Clinical Relevance: The inertial sensor system used to measure asymmetry of head and pelvic movement as an aid in the detection and evaluation of lameness in horses trotting in a straight line was sufficiently repeatable to investigate for clinical use.

Citing Articles

Gait kinematics at trot before and after repeated ridden exercise tests in young Friesian stallions during a fatiguing 10-week training program.

Siegers E, Parmentier J, Sloet van Oldruitenborgh-Oosterbaan M, Munsters C, Serra Braganca F Front Vet Sci. 2025; 12:1456424.

PMID: 39995550 PMC: 11848856. DOI: 10.3389/fvets.2025.1456424.


Quantitative lameness assessment in horses by using an accelerometer-based simple device: A preliminary study.

Crecan C, Ciulu-Angelescu V, Morar I, Lupsan A, Tripon M, Bungardean D Open Vet J. 2024; 14(11):3089-3099.

PMID: 39737023 PMC: 11682783. DOI: 10.5455/OVJ.2024.v14.i11.38.


Repeatability of swimming activity of the Patagonian grouper based on accelerometry.

Venerus L, Domenici P, Marras S, Beltramino L, Ciancio J Conserv Physiol. 2024; 12(1):coae074.

PMID: 39474043 PMC: 11519044. DOI: 10.1093/conphys/coae074.


Effect of circle, surface type and stride duration on vertical head and pelvis movement in riding horses with pre-existing movement asymmetries in trot.

Marunova E, Hernlund E, Persson-Sjodin E PLoS One. 2024; 19(8):e0308996.

PMID: 39150961 PMC: 11329133. DOI: 10.1371/journal.pone.0308996.


Inertial Sensor-Based Quantification of Movement Symmetry in Trotting Warmblood Show-Jumping Horses after "Limb-by-Limb" Re-Shoeing of Forelimbs with Rolled Rocker Shoes.

Bark C, Reilly P, Weller R, Pfau T Sensors (Basel). 2024; 24(15).

PMID: 39123895 PMC: 11315053. DOI: 10.3390/s24154848.