» Articles » PMID: 2187731

Acoustic Artifacts and Reverberation Shadows in Gallbladder Sonograms: Their Cause and Clinical Implications

Overview
Date 1990 Jan 1
PMID 2187731
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

From among more than 7000 sonographic examinations of the gallbladder performed over a period of 2 years, different types of acoustic artifacts were observed in 42 patients. Artifacts originated in the gallbladder wall in 37 cases and within the lumen in 5 cases. Eighteen patients had symptoms related to the hepatobiliary area. Twenty-four patients were fully asymptomatic although cholelithiasis was demonstrated in 8. In 21 cases (50%) some type of gallbladder pathology was associated with the presence of acoustic artifacts. Thirteen patients were cholecystectomized and the associated gallbladder pathology consisted of cholelithiasis (N = 5), cholesterolosis (N = 2), adenomyomatosis (N = 2), emphysematous cholecystitis (N = 2), and acute cholecystitis (N = 2). In 3 of these patients a sonographic/pathologic correlation was established. Only 5 of the 18 symptomatic patients presented acoustic artifacts in an otherwise normal gallbladder. Recognition of those pathological conditions favorable to the appearance of artifacts and reverberation shadows is extremely useful for differentiating merely clinically irrelevant anomalies from those that require prompt management.

Citing Articles

Refraction artifact on abdominal sonogram.

Naganuma H, Ishida H, Uno A, Nagai H, Ogawa M, Kamiyama N J Med Ultrason (2001). 2021; 48(3):273-283.

PMID: 34021821 DOI: 10.1007/s10396-021-01097-z.


Diagnostic problems in two-dimensional shear wave elastography of the liver.

Naganuma H, Ishida H, Uno A, Nagai H, Kuroda H, Ogawa M World J Radiol. 2020; 12(5):76-86.

PMID: 32549956 PMC: 7288776. DOI: 10.4329/wjr.v12.i5.76.


Range-ambiguity artifact in abdominal ultrasound.

Naganuma H, Ishida H, Nagai H, Ogawa M, Ohyama Y J Med Ultrason (2001). 2019; 46(3):317-324.

PMID: 30888535 DOI: 10.1007/s10396-019-00938-2.

References
1.
Good L, Edell S, Soloway R, Trotman B, Mulhern C, Arger P . Ultrasonic properties of gallstones. Effect of stone size and composition. Gastroenterology. 1979; 77(2):258-63. View

2.
Avruch L, Cooperberg P . The ring-down artifact. J Ultrasound Med. 1985; 4(1):21-8. DOI: 10.7863/jum.1985.4.1.21. View

3.
Parulekar S . Sonographic findings in acute emphysematous cholecystitis. Radiology. 1982; 145(1):117-9. DOI: 10.1148/radiology.145.1.7122865. View

4.
Ziskin M, Thickman D, Goldenberg N, LAPAYOWKER M, Becker J . The comet tail artifact. J Ultrasound Med. 1982; 1(1):1-7. DOI: 10.7863/jum.1982.1.1.1. View

5.
Lebensart P, BLOOM R, Meretyk S, Landau E, Shiloni E . Oral cholecystosonography: a method for facilitating the diagnosis of cholesterol gallstones. Radiology. 1984; 153(1):255-6. DOI: 10.1148/radiology.153.1.6473795. View