» Articles » PMID: 21750946

Corneal Topographic Changes After Transconjunctival 23-gauge Sutureless Vitrectomy

Overview
Journal Int Ophthalmol
Specialty Ophthalmology
Date 2011 Jul 14
PMID 21750946
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

To evaluate the topographic changes of cornea after pars plana vitrectomy (PPV) with the 23-gauge- (23-G) transconjunctival sutureless vitrectomy (TSV) system within the first postoperative month. In this prospective study, corneal topographic changes were evaluated in 24 eyes of 24 patients who underwent PPV with the 23-G TSV system. All eyes underwent computer-assisted videokeratography using NAVIS (Nidek Advanced Vision Information System) software preoperatively and at the first day, first week, and first month postoperatively. The topographic parameters that were analyzed statistically were the average corneal power (ACP), corneal surface cylinder (CSC), surface asymmetry index (SAI), and surface regularity index (SRI). Mean induced astigmatism was estimated by vector analysis software. The Wilcoxon test was used for statistical analysis. Mean ACP was 43.12±1.16 diopters (D) preoperatively and 42.88±1.44 D at first day (P=0.301), 43.04±1.14 D at first week (P=0.796), and 43.32±1.17 D at first month postoperatively (P=0.187). Mean CSC was 0.61±0.32 D preoperatively and 0.71±0.48 D at first day (P=0.918), 0.60±0.25 D at first week (P=0.826), and 0.70±0.33 D at first month postoperatively (P=0.414). Mean SAI was 0.12±0.05 preoperatively and 0.21±0.16 at first day (P=0.070), 0.15±0.06 at first week (P=0.176), and 0.16±0.09 at first month postoperatively (P=0.198). Mean SRI was 0.41±0.37 preoperatively and 1.05±0.41 at first day (P=0.001), 0.54±0.42 at first week (P=0.211), and 0.41±0.5 at first month postoperatively (P=0.861). Mean surgically induced astigmatism was 0.67±0.7 D at first day, 0.36±0.2 D at first week, and 0.33±0.17 D at first month postoperatively. Corneal surface and astigmatic changes were observed to be insignificant in the early postoperative period after PPV with the 23-G TSV system.

Citing Articles

Corneal Astigmatism Alteration after Combined Silicone Oil Removal and Cataract Surgery with Intraocular Lens Implantation.

Ji Z, Su T, Li L, He T, Su Y J Ophthalmol. 2023; 2023:6175272.

PMID: 37415780 PMC: 10322570. DOI: 10.1155/2023/6175272.


Evaluation of corneal topographic changes and surgically induced astigmatism after transconjunctival 27-gauge microincision vitrectomy surgery.

Tekin K, Sonmez K, Inanc M, Ozdemir K, Goker Y, Yilmazbas P Int Ophthalmol. 2017; 38(2):635-643.

PMID: 28361378 DOI: 10.1007/s10792-017-0507-5.


Corneal topographic changes and surgically induced astigmatism following combined phacoemulsification and 25-gauge vitrectomy.

Sayed K, Farouk M, Katome T, Nagasawa T, Naito T, Mitamura Y Int J Ophthalmol. 2017; 10(1):72-76.

PMID: 28149780 PMC: 5225352. DOI: 10.18240/ijo.2017.01.12.


Refractive shift of silicone oil tamponade in pseudophakic eye.

Fang W, Li J, Jin X, Zhai J, Dai Y, Li Y BMC Ophthalmol. 2016; 16:144.

PMID: 27526710 PMC: 4986366. DOI: 10.1186/s12886-016-0243-z.


Clinical outcomes of 23-gauge vitrectomy may be better than 20-gauge vitrectomy for retinal detachment repair.

Xia F, Jiang Y Mol Vis. 2015; 21:893-900.

PMID: 26392739 PMC: 4556160.


References
1.
Fujii G, de Juan Jr E, Humayun M, Chang T, Pieramici D, Barnes A . Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology. 2002; 109(10):1814-20. DOI: 10.1016/s0161-6420(02)01119-3. View

2.
Alba-Bueno F, Beltran-Masgoret A, Sanjuan C, Biarnes M, Marin J . Corneal shape changes induced by first and second generation silicone hydrogel contact lenses in daily wear. Cont Lens Anterior Eye. 2009; 32(2):88-92. DOI: 10.1016/j.clae.2008.11.002. View

3.
Fiore Jr J, Newton J . Anterior segment changes following the scleral buckling procedure. Arch Ophthalmol. 1970; 84(3):284-7. DOI: 10.1001/archopht.1970.00990040286005. View

4.
Domniz Y, Cahana M, Avni I . Corneal surface changes after pars plana vitrectomy and scleral buckling surgery. J Cataract Refract Surg. 2001; 27(6):868-72. DOI: 10.1016/s0886-3350(00)00755-0. View

5.
Wilson S, Verity S, Conger D . Accuracy and precision of the corneal analysis system and the topographic modeling system. Cornea. 1992; 11(1):28-35. DOI: 10.1097/00003226-199201000-00004. View