» Articles » PMID: 21747732

An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

Overview
Date 2011 Jul 13
PMID 21747732
Authors
Affiliations
Soon will be listed here.
Abstract

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4',4''-methylidynetris (N,N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 μg of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1)  ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1)  ClO(-), a detection limit of 6.0 μg L(-1)  ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 μL per determination.

References
1.
Melchert W, Rocha F . A greener and highly sensitive flow-based procedure for carbaryl determination exploiting long pathlength spectrophotometry and photochemical waste degradation. Talanta. 2010; 81(1-2):327-33. DOI: 10.1016/j.talanta.2009.12.005. View

2.
Mesquita R, Noronha M, Pereira A, Santos A, Torres A, Cerda V . Use of tetramethylbenzidine for the spectrophotometric sequential injection determination of free chlorine in waters. Talanta. 2008; 72(3):1186-91. DOI: 10.1016/j.talanta.2007.01.010. View

3.
Puget S, Beno N, Chabanet C, Guichard E, Thomas-Danguin T . Tap water consumers differ from non-consumers in chlorine flavor acceptability but not sensitivity. Water Res. 2009; 44(3):956-64. DOI: 10.1016/j.watres.2009.10.009. View

4.
Rodenas-Torralba E, Rocha F, Reis B, Morales-Rubio A, de la Guardia M . Evaluation of a multicommuted flow system for photometric environmental measurements. J Autom Methods Manag Chem. 2007; 2006:20384. PMC: 1903455. DOI: 10.1155/JAMMC/2006/20384. View

5.
Feres M, Reis B . A downsized flow set up based on multicommutation for the sequential photometric determination of iron(II)/iron(III) and nitrite/nitrate in surface water. Talanta. 2008; 68(2):422-8. DOI: 10.1016/j.talanta.2005.09.001. View