» Articles » PMID: 21724068

Cone-beam Computed Tomography to Detect Erosions of the Temporomandibular Joint: Effect of Field of View and Voxel Size on Diagnostic Efficacy and Effective Dose

Overview
Publisher Elsevier
Specialty Dentistry
Date 2011 Jul 5
PMID 21724068
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: In this study, we examined the influence of field of view (FOV) and voxel size on the diagnostic efficacy of cone-beam computed tomography (CBCT) scans to detect erosions in the temporomandibular joint (TMJ).

Methods: The sample consisted of 16 TMJs containing natural or artificially created erosions and 16 normal TMJs. CBCT scans were obtained with 3 imaging protocols differing in the FOV and the size of the reconstructed voxels. Two oral and maxillofacial radiologists scored the scans for the presence or absence of erosions. Diagnostic efficacies of the 3 imaging protocols were compared by using receiver operating curve analysis. For each TMJ imaging protocol, we used thermoluminescent dosimetry chips to measure the absorbed dose at specific organ and tissue sites. Effective doses for each examination were calculated.

Results: Areas under the receiver operating characteristic curves were 0.77 ± 0.05 for the 6-in FOV, 0.70 ± 0.08 for the 9-in FOV, and 0.66 ± 0.05 for the 12-in FOV. The diagnostic efficacy of the 6-in FOV, determined by the area under the curve, was significantly higher than that of the 12-in FOV (P ≤0.05). Effective doses for bilateral TMJ evaluation were 558 μSv for the 6-in FOV, 548 μSv for the 9-in FOV, and 916 μSv for the 12-in FOV.

Conclusions: The diagnostic efficacy of CBCT scans for the evaluation of erosive changes in the TMJ is highest for the 6-in FOV and lowest for the 12-in FOV.

Citing Articles

Assessment of variations in the nasopalatine canal on CBCT: considerations from an anatomical point of view.

Yadav U, Shenoy N, Ahmed J, Sujir N, M A, Gupta A J Periodontal Implant Sci. 2024; 55(1):62-71.

PMID: 39058352 PMC: 11885867. DOI: 10.5051/jpis.2401300065.


Modifications of the articular eminence inclination in association with the loss of occlusal support in the molar area. A cone-beam computed tomography study.

Virlan M, Nimigean V, Paun D, Bisoc A, Nimigean V Rom J Morphol Embryol. 2024; 65(2):297-307.

PMID: 39020545 PMC: 11384045. DOI: 10.47162/RJME.65.2.17.


Evaluation of Rheumatic Diseases Affecting the Temporomandibular Joint: A Cone Beam Computed Tomography Study and Literature Review.

Merve Semerci Z, Gunen Yilmaz S Diagnostics (Basel). 2024; 14(1).

PMID: 38201313 PMC: 10795630. DOI: 10.3390/diagnostics14010004.


Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations.

Deniz Y, Eren H, Sessiz R, Cosan Ata G Radiat Environ Biophys. 2024; 63(1):39-45.