» Articles » PMID: 21721715

Frequency-shift Vs Phase-shift Characterization of In-liquid Quartz Crystal Microbalance Applications

Overview
Journal Rev Sci Instrum
Date 2011 Jul 5
PMID 21721715
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequency/mass sensitivity with the square of frequency predicted by Sauerbrey. However, this sensitivity improvement has not been completely transferred in terms of resolution. The decrease of frequency stability due to the increase of the phase noise, particularly in oscillators, made impossible to reach the expected resolution. A new concept of sensor characterization at constant frequency has been recently proposed. The validation of the new concept is presented in this work. An immunosensor application for the detection of a low molecular weight contaminant, the insecticide carbaryl, has been chosen for the validation. An, in principle, improved version of a balanced-bridge oscillator is validated for its use in liquids, and applied for the frequency shift characterization of the QCM immunosensor application. The classical frequency shift characterization is compared with the new phase-shift characterization concept and system proposed.

Citing Articles

Piezoelectric biosensors: shedding light on principles and applications.

Skladal P Mikrochim Acta. 2024; 191(4):184.

PMID: 38451295 PMC: 10920441. DOI: 10.1007/s00604-024-06257-9.


A Real-Time Method for Improving Stability of Monolithic Quartz Crystal Microbalance Operating under Harsh Environmental Conditions.

Fernandez R, Calero M, Jimenez Y, Arnau A Sensors (Basel). 2021; 21(12).

PMID: 34204556 PMC: 8235264. DOI: 10.3390/s21124166.


Studying Soft Interfaces with Shear Waves: Principles and Applications of the Quartz Crystal Microbalance (QCM).

Johannsmann D, Langhoff A, Leppin C Sensors (Basel). 2021; 21(10).

PMID: 34067761 PMC: 8157064. DOI: 10.3390/s21103490.


GHz Ultrasonic Chip-Scale Device Induces Ion Channel Stimulation in Human Neural Cells.

Balasubramanian P, Singh A, Xu C, Lal A Sci Rep. 2020; 10(1):3075.

PMID: 32080204 PMC: 7033194. DOI: 10.1038/s41598-020-58133-0.


Quartz Crystal Microbalance Electronic Interfacing Systems: A Review.

Alassi A, Benammar M, Brett D Sensors (Basel). 2017; 17(12).

PMID: 29206212 PMC: 5750807. DOI: 10.3390/s17122799.