Confidence Interval Estimation for the Bland-Altman Limits of Agreement with Multiple Observations Per Individual

Overview
Publisher Sage Publications
Specialties Public Health
Science
Date 2011 Jun 28
PMID 21705434
Citations 85
Authors
Affiliations
Soon will be listed here.
Abstract

The limits of agreement (LoA) method proposed by Bland and Altman has become a standard for assessing agreement between different methods measuring the same quantity. Virtually, all method comparison studies have reported only point estimates of LoA due largely to the lack of simple confidence interval procedures. In this article, we address confidence interval estimation for LoA when multiple measurements per individual are available. Separate procedures are proposed for situations when the underlying true value of the measured quantity is assumed changing and when it is perceived as stable. A fixed number of replicates per individual is not needed for the procedures to work. As shown by the worked examples, the construction of these confidence intervals requires only quantiles from the standard normal and chi-square distributions. Simulation results show the proposed procedures perform well. A SAS macro implementing the methods is available on the publisher's website.

Citing Articles

Validation of the capnodynamic method to calculate mixed venous oxygen saturation in postoperative cardiac patients.

Wallin M, Hallback M, Iftikhar H, Keleher E, Aneman A Intensive Care Med Exp. 2025; 13(1):32.

PMID: 40053202 PMC: 11889286. DOI: 10.1186/s40635-025-00741-z.


DiCART device to measure capillary refill time: a validation study in patients with acute circulatory failure.

Descamps A, Jacquet-Lagreze M, Aussal T, Fellahi J, Ruste M J Clin Monit Comput. 2025; .

PMID: 40011397 DOI: 10.1007/s10877-025-01271-5.


Validation of a Multi-Channel Ambient Sensor to Measure Vital Signs in Patients Within the Ward and at Home.

Lim S, Li P, Braat S, Aung Y, Fu S, Johnson D Sensors (Basel). 2025; 25(4).

PMID: 40006378 PMC: 11859041. DOI: 10.3390/s25041149.


Performance of inflationary oscillometric blood pressure measurement in the presence of atrial fibrillation: comparison to sinus rhythm.

Maki Y, Sakamoto Y, Abe R, Morozumi K, Toyoda D, Kotake Y J Anesth. 2025; .

PMID: 39966135 DOI: 10.1007/s00540-025-03462-5.


Accuracy of remote, video-based supraventricular tachycardia detection in patients undergoing elective electrical cardioversion: a prospective cohort.

Cramer I, van Esch R, Verstappen C, Kloeze C, van Bussel B, Stuijk S J Clin Monit Comput. 2025; .

PMID: 39881085 DOI: 10.1007/s10877-025-01263-5.