» Articles » PMID: 2168451

The British Hypertension Society Protocol for the Evaluation of Automated and Semi-automated Blood Pressure Measuring Devices with Special Reference to Ambulatory Systems

Overview
Journal J Hypertens
Date 1990 Jul 1
PMID 2168451
Citations 143
Authors
Affiliations
Soon will be listed here.
Abstract

With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many features of the American National Standard for Non-Automated Sphygmomanometers but includes many additional features, such as strict criteria for observer training, interdevice variability testing before and after a month of ambulatory use, and a new system of analysis which permits the test system to be graded. It is recommended that manufacturers of ambulatory blood pressure measuring devices should obtain an unbiased evaluation according to a recognized standard before a device is marketed.

Citing Articles

Real-time Continuous Blood Pressure Estimation with Contact-free Bedseismogram.

Song Y, Li B, Luo D, Brewster Glasgow G, Phillips B, Ke Y IEEE Int Conf Commun. 2024; 2024:214-219.

PMID: 39583890 PMC: 11583795. DOI: 10.1109/icc51166.2024.10622995.


Non-invasive versus arterial pressure monitoring in the pre-hospital critical care environment: a paired comparison of concurrently recorded measurements.

Perera Y, Raitt J, Poole K, Metcalfe D, Lewinsohn A Scand J Trauma Resusc Emerg Med. 2024; 32(1):77.

PMID: 39192296 PMC: 11348748. DOI: 10.1186/s13049-024-01240-y.


Association of meeting the 24-h movement guidelines with high blood pressure in adolescents: a cross-sectional study.

Christofaro D, Ferrari G, Cucato G, Mota J, Silva D, Vanderlei L Sci Rep. 2024; 14(1):17060.

PMID: 39048634 PMC: 11269724. DOI: 10.1038/s41598-024-68063-w.


Continuous blood pressure prediction system using Conv-LSTM network on hybrid latent features of photoplethysmogram (PPG) and electrocardiogram (ECG) signals.

Kamanditya B, Fuadah Y, T N, Lim K Sci Rep. 2024; 14(1):16450.

PMID: 39014018 PMC: 11252121. DOI: 10.1038/s41598-024-66514-y.


History and evolution of blood pressure measurement.

Noh S, Kim H, Kang S, Yoon C, Youn T, Chae I Clin Hypertens. 2024; 30(1):9.

PMID: 38556854 PMC: 10983645. DOI: 10.1186/s40885-024-00268-7.