» Articles » PMID: 21641247

Quantitative Separation of CEST Effect from Magnetization Transfer and Spillover Effects by Lorentzian-line-fit Analysis of Z-spectra

Overview
Journal J Magn Reson
Publisher Elsevier
Date 2011 Jun 7
PMID 21641247
Citations 151
Authors
Affiliations
Soon will be listed here.
Abstract

Chemical exchange saturation transfer (CEST) processes in aqueous systems are quantified by evaluation of z-spectra, which are obtained by acquisition of the water proton signal after selective RF presaturation at different frequencies. When saturation experiments are performed in vivo, three effects are contributing: CEST, direct water saturation (spillover), and magnetization transfer (MT) mediated by protons bound to macromolecules and bulk water molecules. To analyze the combined saturation a new analytical model is introduced which is based on the weak-saturation-pulse (WSP) approximation. The model combines three single WSP approaches to a general model function. Simulations demonstrated the benefits and constraints of the model, in particular the capability of the model to reproduce the ideal proton transfer rate (PTR) and the conventional MT rate for moderate spillover effects (up to 50% direct saturation at CEST-resonant irradiation). The method offers access to PTR from z-spectra data without further knowledge of the system, but requires precise measurements with dense saturation frequency sampling of z-spectra. PTR is related to physical parameters such as concentration, transfer rates and thereby pH or temperature of tissue, using either exogenous contrast agents (PARACEST, DIACEST) or endogenous agents such as amide protons and -OH protons of small metabolites.

Citing Articles

Improving quantification accuracy of a nuclear Overhauser enhancement signal at -1.6 ppm at 4.7 T using a machine learning approach.

Yin L, Viswanathan M, Kurmi Y, Zu Z Phys Med Biol. 2025; 70(2.

PMID: 39774035 PMC: 11740009. DOI: 10.1088/1361-6560/ada716.


Multiparametric Chemical Exchange Saturation Transfer MRI Detects Metabolic Changes in Mild Cognitive Impairment Cases at 3.0 Tesla.

Zhu D, Fu X, Liu J, Liu X, Cheng L, Zhang X Neurochem Res. 2024; 50(1):51.

PMID: 39648256 DOI: 10.1007/s11064-024-04307-5.


Ungated, plug-and-play preclinical cardiac CEST-MRI using radial FLASH with segmented saturation.

Weigand-Whittier J, Wendland M, Lam B, Velasquez M, Vandsburger M Magn Reson Med. 2024; 93(4):1793-1806.

PMID: 39607872 PMC: 11785487. DOI: 10.1002/mrm.30382.


Motion and magnetic field inhomogeneity correction techniques for chemical exchange saturation transfer (CEST) MRI: A contemporary review.

Simegn G, Sun P, Zhou J, Kim M, Reddy R, Zu Z NMR Biomed. 2024; 38(1):e5294.

PMID: 39532518 PMC: 11606773. DOI: 10.1002/nbm.5294.


Amide proton transfer-weighted CEST MRI for radiotherapy target delineation of glioblastoma: a prospective pilot study.

Tang P, Mendez Romero A, Nout R, van Rij C, Slagter C, Swaak-Kragten A Eur Radiol Exp. 2024; 8(1):123.

PMID: 39477835 PMC: 11525355. DOI: 10.1186/s41747-024-00523-4.