» Articles » PMID: 21622068

Dielectric Characterization of PCL-based Thermoplastic Materials for Microwave Diagnostic and Therapeutic Applications

Overview
Date 2011 May 31
PMID 21622068
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

We propose the use of a polycaprolactone (PCL)-based thermoplastic mesh as a tissue-immobilization interface for microwave imaging and microwave hyperthermia treatment. An investigation of the dielectric properties of two PCL-based thermoplastic materials in the frequency range of 0.5-3.5 GHz is presented. The frequency-dependent dielectric constant and effective conductivity of the PCL-based thermoplastics are characterized using measurements of microstrip transmission lines fabricated on substrates comprised of the thermoplastic meshes. We also examine the impact of the presence of a PCL-based thermoplastic mesh on microwave breast imaging. We use a numerical test bed comprised of a previously reported 3-D anatomically realistic breast phantom and a multi-frequency microwave inverse scattering algorithm. We demonstrate that the PCL-based thermoplastic material and the assumed biocompatible medium of vegetable oil are sufficiently well matched such that the PCL layer may be neglected by the imaging solution without sacrificing imaging quality. Our results suggest that PCL-based thermoplastics are promising materials as tissue immobilization structures for microwave diagnostic and therapeutic applications.

Citing Articles

Printable devices for neurotechnology.

Matta R, Moreau D, OConnor R Front Neurosci. 2024; 18:1332827.

PMID: 38440397 PMC: 10909977. DOI: 10.3389/fnins.2024.1332827.


A Surface Imprinted Polymer EIS Sensor for Detecting Alpha-Synuclein, a Parkinson's Disease Biomarker.

Massey R, Appadurai R, Prakash R Micromachines (Basel). 2024; 15(2).

PMID: 38399001 PMC: 10892569. DOI: 10.3390/mi15020273.


Dielectric properties of 3D-printed materials for anatomy specific 3D-printed MRI coils.

Behzadnezhad B, Collick B, Behdad N, McMillan A J Magn Reson. 2018; 289:113-121.

PMID: 29500942 PMC: 5856656. DOI: 10.1016/j.jmr.2018.02.013.


3D microwave tomography of the breast using prior anatomical information.

Golnabi A, Meaney P, Paulsen K Med Phys. 2016; 43(4):1933.

PMID: 27036589 PMC: 4808070. DOI: 10.1118/1.4944592.


Quantitative Microwave Imaging of Realistic Numerical Breast Phantoms Using an Enclosed Array of Multiband, Miniaturized Patch Antennas.

Burfeindt M, Behdad N, Van Veen B, Hagness S IEEE Antennas Wirel Propag Lett. 2014; 11:1626-1629.

PMID: 25419189 PMC: 4237205. DOI: 10.1109/LAWP.2012.2236071.


References
1.
Al-Joumayly M, Aguilar S, Behdad N, Hagness S . Dual-Band Miniaturized Patch Antennas for Microwave Breast Imaging. IEEE Antennas Wirel Propag Lett. 2011; 9:268. PMC: 3159566. DOI: 10.1109/LAWP.2010.2045871. View

2.
Vargas H, Dooley W, Gardner R, Gonzalez K, Venegas R, Heywang-Kobrunner S . Focused microwave phased array thermotherapy for ablation of early-stage breast cancer: results of thermal dose escalation. Ann Surg Oncol. 2004; 11(2):139-46. DOI: 10.1245/aso.2004.03.059. View

3.
Heywang-Kobrunner S, Heinig A, Pickuth D, Alberich T, Spielmann R . Interventional MRI of the breast: lesion localisation and biopsy. Eur Radiol. 2000; 10(1):36-45. DOI: 10.1007/s003300050005. View

4.
deSouza N, Kormos D, Krausz T, Coutts G, Hall A, Burl M . MR-guided biopsy of the breast after lumpectomy and radiation therapy using two methods of immobilization in the lateral decubitus position. J Magn Reson Imaging. 1995; 5(5):525-8. DOI: 10.1002/jmri.1880050508. View

5.
Meaney P, Fanning M, Raynolds T, Fox C, Fang Q, Kogel C . Initial clinical experience with microwave breast imaging in women with normal mammography. Acad Radiol. 2007; 14(2):207-18. PMC: 1832118. DOI: 10.1016/j.acra.2006.10.016. View